If you notice after several hours of use that smoke is coming out of the
the sides of the loading hatch closed, the duct does not have enough draft. It must
therefore be enhanced. It is imperative that the duct exceeds at least 50 cm the
highest point of the roof called "ridge" and in any case, higher than 50 cm of any
obstacle around the duct. (building nearby)
The chimney will be insulated and will never have a horizontal part according to the
regulations in force.
Depending on the regulations in force in the geographical area concerned, it may
be necessary to install particle filtration on the smoke evacuation network.
In the event of an electrical fault or fan malfunction, first make sure that:
•
The power supply is correct.
•
There are no voltage variations greater than + 10% or -15%.
•
The fuses are in good condition.
•
There is no shortage of solid fuel.
NOTE: Any repairs must be carried out by qualified technical personnel using original
spare parts. It is forbidden to open or manipulate the components of the generator, with
the exception of those provided for maintenance.
NEVER TURN ON THE GENERATOR WITHOUT CONNECTING THE
ELECTRIC NETWORK FAN
NEVER DISCONNECT THE POWER WHEN THE APPLIANCE IS HOT
Since the thermal energy accumulated in the combustion chamber and the heat exchanger
can damage the electric fan unit and the heat exchanger.
DO NOT TOUCH THE PARTS EXPOSED TO HEAT RADIATION in particular the
loading door, the nozzle and the uninsulated duct.
WARNING :
It is imperative to keep a respectable distance when opening the hatch to avoid
any risk of burns.
6
02/04/2019
2.4
IRREGULARITIES IN OPERATION AND PRECAUTIONS
CAUSES AND SOLUTIONS