Flexiheat FH100ECP Installation Instructions Manual Download Page 3

This hot air generator works with solid vegetable fuels; it is a device whose operating principle is 

the production of direct heat through the use of thermal energy produced by combustion.

Heat exchange is produced when a flow of air generated by a fan is passed through the internal 

surfaces of the heat exchanger, without the aid of any intermediate fluid so called direct 

exchange. In addition, part of the thermal energy is produced by the low temperature radiation of 

the machine.

The gaseous residues resulting from the combustion (fumes), when the heat exchange is carried out, 

are expelled outside through the flue gas pipe at a temperature of approximately 280 ° C at maximum 

developed power.

The solid residues of gasoline combustion (ash) fall naturally thanks to a stainless steel grate in an 

ashtray drawer in the lower part.

This appliance is used for heating industrial environments and meets these standards. It can also 

be used for any other application, in this case, refer to the specific standards.

To) 

A rectangular-shaped combustion chamber briquetted by refractory elements.

b) 

A tilting hatch for loading solid fuels.

vs) 

A tubular heat exchanger with a large surface area with natural ventilation fairing.

d) 

A perforated ash collection drawer with adjustable primary combustion air intake ruler.

e) 

A chimney nozzle fitted with a draft key through which the combustion residues pass to be 

expelled through the smoke duct outside the heated enclosure.

• 

Ventilation group

The device is equipped with a medium pressure centrifugal fan which allows the connection of a 

distribution duct.

• 

Chimney nozzle

The appliance is equipped with a circular outlet of a standard diameter where it is possible to connect and 

securely fix a metal flue (preferably insulated) to evacuate the gaseous residues resulting from the 

combustion to the outside. The draft key integrated into the nozzle allows the power to be regulated by 

limiting the natural depression.

This duct must have the following characteristics:

• 

Do not add elbows with more than a 45 ° angle and raise the duct in this case by 1m per 45 ° 

elbow

• 

Have an end part of the duct fitted with a cap.

3

02/04/2019

1.1 PRINCIPLE OF FOOPERATION:

2

CONSTRUCTION OF THE APPLIANCE

:

• 

Diameter equal to or greater than the nozzle of the device and without section reductions. (Ø 153 mm 

for 

FH50ECP

 and Ø 200 mm for 

FH100ECP

)

Page

 

The heater

 is made of carbon steel sheet, developed according to European standards. Easy 

to access for normal cleaning and maintenance operations. It is composed of :

It cannot be installed in direct contact with explosive agents or in a flammable 

environment.

Summary of Contents for FH100ECP

Page 1: ...1 02 04 2019 Page INSTALLATION INSTRUCTIONS Wood Warm Air Heaters FH50ECP and FH100ECP Please read carefully the precautions for use and the instructions for use before any installation andcommissioning ...

Page 2: ...r As soon as you decide to stop using the appliance you must not use parts that could constitute a Make sure that these instructions are always included with the device The regulatory protection of the device must be ensured in accordance with the classification standards for the professional premises where it is installed If the appliance is installed in a place where there are disabled people an...

Page 3: ...airing d A perforated ash collection drawer with adjustable primary combustion air intake ruler e A chimney nozzle fitted with a draft key through which the combustion residues pass to be expelled through the smoke duct outside the heated enclosure Ventilation group The device is equipped with a medium pressure centrifugal fan which allows the connection of a distribution duct Chimney nozzle The a...

Page 4: ...raft regulator This duct will be insulated as far as possible in double skin to avoid the dew point 1m after the discharge nozzle We offer an optional STAINLESS STEEL starter kit with buffer to facilitate maintenance by relocating the duct Never horizontal part with 90 elbows Elbow open 45 Elbow 90 Elbow 90 1m Elbow open 45 NO YES 4 02 04 2019 2 1 PACKAGING AND TRANSPORT 2 2 INSTALLATION INSTRUCTI...

Page 5: ...ESSION The draft measurement must be carried out under the shutter which will allow the shutter to be balanced during the measurement The flue gas pipe must never be reduced to a diameter smaller than that of the outlet nozzle However there is no problem if the duct is of a larger diameter In the event of installation on an old masonry duct it is essential to pipe the duct 5 02 04 2019 Page During...

Page 6: ...ect There are no voltage variations greater than 10 or 15 The fuses are in good condition There is no shortage of solid fuel NOTE Any repairs must be carried out by qualified technical personnel using original spare parts It is forbidden to open or manipulate the components of the generator with the exception of those provided for maintenance NEVER TURN ON THE GENERATOR WITHOUT CONNECTING THE ELEC...

Page 7: ...the outside of the heat exchanger tubes if necessary by steam washing using a high pressure cleaner Empty and clean the ash drawer Vacuum the soot in the combustion chamber clean the brickwork Periodically replace damaged bricks see spare parts list Maintenance of the flue gas pipe Disassemble the duct components and carefully sweep the flammable deposit film Electric fan unit Blow out the inside ...

Page 8: ...an to the 240V T electrical network load the fireplace to 30 of its capacity i e around 3 to 4 kg with low density wood but with rapid combustion of species wood from pallets poplars offcuts wooden logs After the total combustion of this charge repeat the operation with 50 of the charge draft key open to the max Commissioning after briquetting Load the appliance with wood or any other non pollutin...

Page 9: ... regulation key Group electro fan Fairing exchanger heat Brickwork refractory ground Hopper air distribution Door of loading Drawer collection of Room of combustion 9 02 04 2019 2 7 EXPLODED VIEW OF THE UNIT Stainless steel grid Page ...

Page 10: ...180 mm 700 mm 1110 mm 1180 mm 780 mm 620 mm 970 mm 182 mm 900 mm 1286 mm 1790 50 mm 845 mm 1340 50 mm 10 02 04 2019 2 8 DIMENSIONS Page Model FH50ECP Model FH100ECP ...

Page 11: ... heating cycle Electrical cabinet V1 Indicator voltage presence P2 Inverter summer Winter Th Thermostat fan Description of the dashboard Thermostat Summer Fuse Stop Winter Voltage presence indicator Probe position thermostatic Passage of the probe thermostatic Position behind the grid In the 220 V mono motor connection box Power cable departure from the cabinet Earth lug 11 02 04 2019 2 9 DESCRIPT...

Page 12: ...the loading that is to say 10 kg of wood for the model FH50ECP or 20 kg of wood for the model FH100ECP Page At 50 power i e around 150 C you can reload the wood heater with fuel to develop the maximum power i e 5 kg for the FH50ECP or 10 kg for the FH100ECP of additional fuel Functioning As soon as the vegetable fuel is burnt the flue gas temperature is indicated on the visual thermal control The ...

Reviews: