![flexicelcrea T13FHL-7 Installation And User Guidance Download Page 16](http://html1.mh-extra.com/html/flexicelcrea/t13fhl-7/t13fhl-7_installation-and-user-guidance_2304650016.webp)
16
3.4.4.2 Floor sensor setting
Set floor sensor type:
The thermostat is compatible with these floor sensors:
NTC10K, NTC15K and NTC100K.
The Factory default is NTC10K, the sensor will be included (see
picture)
Set temperatura offset:
If you feel the room temperature is not very comfortable, you
can set the offset temperature, the maximum limit of the offset
temperature is -4ºC ~ 4ºC. The factory default is 0ºC.
3.4.4.3 Floor temperature limit
In order to protect the floor not to be damaged, you should
set the floor temperature upper limit; turn the dial to set the
temperature according to your floor material.
The Factory default floor temperature is 35oC (20~70oC op-
tional).