![flexicelcrea T13FHL-7 Installation And User Guidance Download Page 15](http://html1.mh-extra.com/html/flexicelcrea/t13fhl-7/t13fhl-7_installation-and-user-guidance_2304650015.webp)
15
3.4.2 Date setting
Press “OK” into the date option, the year will flash first, turn the dial to
set it, Press “OK” and then the month begin to flash, turn the dial to
set it, Press “OK”.
Now the date will flash, turn the dial to set it, press “OK”.
Press it again to edit the time setting (hour, minute, second).
The factory default is 2012.01.01, 12:00AM.
3.4.3 Child lock
The child lock is used for locking the screen, in order to prevent some
false changes by mistake. Turn the dial to select “ON”, the symbol will
appear on the top of the display screen, if you want to turn it off, just
turn the dial to select “OFF”. The factory default is “ON”.“ON”.
3.4.4 Install setting
Control mode select:
Turn the dial to select the control object, there are 3 modes: Room
Mode, Floor Mode and Room temperature with floor limit. The factory
default is Room temperature with floor limit.
Room temperature mode:
The thermostat will use the temperature Reading from the room sensor
(inside thermostat housing) to decide whether heating is required to
achieve the setpoint.
Floor temperature mode:
The thermostat will use the temperature Reading from the floor sensor
to decide whether heating is required to achieve the setpoint.
Room temperature with floor limit:
The thermostat will use the temperature reading from the room sensor
to decide whether heating is required to achieve the setpoint, however
if the floor temperature goes above the set limit (See 3.4.4.3) then hea-
ting will be suspended until floor temperature falls below limit.