20
H-Type
®
Primary Cleaner with V-Tips
• Recheck that all fasteners are tightened properly.
• Add pole caps.
• Apply all supplied labels to the cleaner .
• Check the blade location on the belt.
• Be sure that all installation materials and tools have been removed from the belt and the conveyor area.
6.2 Test Run the Conveyor
• Run the conveyor for at least 15 minutes and inspect the cleaning performance.
• Check the tensioner spring for recommended length (proper tensioning).
• Make adjustments as necessary.
NOTE: Observing the cleaner when it is running and performing properly will help to detect problems or
when adjustments are needed later.
6.1 Pre-Op Checklist
Section 6 – Pre-Operation Checklist and Testing