INSTALLATION INSTRUCTIONS
LINEAR SERIES
IMPORTANT
: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR
SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.
913-851-3000
11-13-17
MAKING ELECTRICAL CONNECTIONS:
STAND ALONE FIXTURE (FXT) ONLY:
1.
FIXTURES WITH OPTIONAL FACTORY-INSTALLED CORD WITH WIRE ENDS (WITHOUT PLUG):
EXTEND CORD AND WIRE ENDS TO NEAREST ELECTRICAL
JUNCTION BOX (PROVIDED BY CONTRACTOR) AND MAKE FINAL ELECTRICAL CONNECTIONS PER ALL APPLICABLE CODES INSIDE JUNCTION BOX -BLACK TO BLACK
(HOT); WHITE TO WHITE (NEUTRAL) AND GREEN (OR BARE) TO GREEN (GROUND); VOILET TO VIOLET AND GREY TO GREY ON 5-WIRE CORD (IF APPLICABLE).
2.
FIXTURES WITH OPTIONAL FACTORY-INSTALLED CORD AND PLUG:
CONNECT CORD AND PLUG TO NEAREST APPROPRIATELY RATED RECEPTACLE (PROVIDED
BY CONTRACTOR).
3.
HARDWIRED FIXTURES – STAND ALONE FIXTURE (FXT):
a.
TAKE NOTE WHERE DRIVER IS LOCATED ON LED LIGHT COVER.
b.
LOCATE DRIVER ON BACKSIDE OF SECTION “A” (ALL MODELS) – IT IS NEAR THE RECTANGLE KNOCKOUT.
c.
CHOOSE A SUITABLE KNOCKOUT LOCATION FROM THOSE PROVIDED IN FIXTURE HOUSING.
d.
REMOVE THE KNOCKOUT WITH A SCREWDRIVER.
e.
PULL EXISTING AC POWER FROM BUILDING THROUGH KNOCKOUT LOCATION INTO FIXTURE HOUSING. PROVIDE UL APPROVED STRAIN RELIEF (NOT
PROVIDED) AS REQUIRED.