background image

MANUFACTURER / IMPORTER 

 

TEST LABORATORY 

 

 

This is the result of test, that was carried out from the 
submitted type-samples of a product in conformity with the 
specification of the respective standards. 
The declaration holder has the right to fix the CE-mark for 
EMC on the product complying with the inspection sample

 

 

 

 

 

 

09 August 2014 

 

(Date)  

(Date) 

 

 

 

 

 

 

(Surname, forename) 

 

(Company stamp) 

(Company stamp) 

CTS (Ningbo) Testing Service Technology Co., Ltd.

 

 

NB test site:2/F., South Tower, Huoju Building, No.181, Canghai 
Road, Jiangdong Science and Technology Park, Ningbo, 
Zhejiang, China

 

 

GZ test site: A101, No.65, Zhuji Road, Tianhe District,  
Guangzhou, Guangdong, China 

 

CTS (NINGBO) TESTING SERVICE TECHNOLOGY 

OPERATE ACCORDING TO ISO/IEC 17025 

EC DECLARATION OF CONFORMITY 

EU      - ELECTROMAGNETIC COMPATIBILITY DIRECTIVE - 

This declares that the following designated product 

 

Emergency Panel 

Model No.:   FLP-IP6723,    

FLP-EP9060,   

FLP-EP9060B,  

FLP-MP9010B,   FLP-PS9800MKII,  FLP-ZS9810 

Brand Name: FLEPCHER 

Product identification

 

Complies with the essential protection requirements of the European Parliament and of the 

Council Directive 2004/108/EC on the approximation of the laws of the Member States relating 

to electromagnetic compatibility. 

This declaration applies to all specimens manufactured in accordance with the attached 

manufacturing drawings which form part of this declaration. 

Assessment of compliance of the product with the requirements relating to electromagnetic 

compatibility was based on the following standards: 

EN 55013: 2013 

EN 61000-3-2: 2006+A2:2009, EN 61000-3-3: 2008 

EN

 

55020:2007+A11 :2011

 

 

(Identification of regulations / standards) 

This declaration is the responsibility of the Applicant / importer 

 

Flepcher Sdn Bhd 

9, Jalan Kenari 10, Bandar Puchong Jaya, 47100 Puchong,   

Selangor, Malaysia 

  (Name / Address) 

   

 

 

 

THIS DOC IS ONLY VALID IN CONNECTION WITH TEST REPORT NUMBER: CGZ3140702-00690-E-D 

Summary of Contents for FLP-EP9060

Page 1: ...y when a physical activation is called for FLP EP 9060 Emergency Panel Generate EMC signal One minute recording function for MIC and LINE IN music Volume control for output microphone Automatic or man...

Page 2: ...is unit We also recommend that you keep this manual handy for future reference OPERATION MANUAL FLP EP9060 ALARMING SIGNAL GENERATOR PUBLIC ADDRESS SYSTEM TM VOL PLAY MSG MIC in PLAY SIREN REC in ON O...

Page 3: ...ECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 6 5 7 6 APPLICATIONS 8 7 SPECIFICATIONS 9 8 DIMENSIONAL DIAGRAM 10 MACHINE OPERATION TABL...

Page 4: ...doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these termin...

Page 5: ...k When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall...

Page 6: ...l public address solution from small to big places such us mosques schools hotels and factories to train stadium and air stations 2 GENERAL DESCRIPTION 1 2 3 4 With alarm trigger and siren output One...

Page 7: ...ecording LINE Line recording 6 POWER Power indicator 7 STANDBY SWITCH 1 Always power indicator light keyboard operable 0 Power indicator light flashes the keyboard can not operate VOL PLAY MSG MIC in...

Page 8: ...ess play knob then it has a short siren output press alarm mode and select longalarming mode press play knob again and it has a longsiren output 1 Siren alarms when you set the optional switch at SIRE...

Page 9: ...250V FUSE ALARM IN ALARM OUT MIC IN REC IN EMERGENCY ALARM INPUT MIC 4 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 OUTPUT AUX 3 AUX 2 AUX 1 INPUT INPUT MIC 4 MIC 5 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2 LINE INPUT MIXER PRE...

Page 10: ...P9060 DIMENSION mm NET WEIGHT GROSS WEIGHT 484X209X44 POWER CONSUMPTION POWER REQUIREMENTS 5 2Kg 4Kg 30W Power LED Alarm work of the police state of indicator INDICATORS 9 220 240V 50 60Hz Specific vo...

Page 11: ...ART 8 DIMENSIONAL DIAGRAM UNIT mm 6 41 41 296 290 44 50 440 484 10cmMore 10cmMore 10cmMore 10 USE ONLY WITHA 250V FUSE USE ONLY WITHA 250V FUSE ALARM IN ALARM OUT MIC IN REC IN VOL PLAY MSG MIC in PLA...

Page 12: ...PUBLIC ADDRESS SYSTEM PUBLIC ADDRESS SYSTEM VersionV0 2 TM...

Page 13: ...roduct Emergency Panel Model No FLP IP6723 FLP EP9060 FLP EP9060B FLP MP9010B FLP PS9800MKII FLP ZS9810 Brand Name FLEPCHER Product identification Complies with the essential protection requirements o...