22 

 

“FCB” Door Spout Assembly and Related Parts 

 

 

 

Figure 3D 

3A

3B

3C

2A

2

4H

4

4B

4G

4E

4D

4B

4F

4A

4A

4C

5

6

7

8

1

3

1B

1A

D

FOR “FCB” SYSTEMS

26003D

Summary of Contents for CTP 80BEV-INT-2S

Page 1: ...r pricing ordering and support contact one of our qualified distributors PLEASE READ FIRST This supplement is not a full operations manual It does not contain complete information on installing and ma...

Page 2: ...1 PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...onmental Notices 5 Parts Identification Function 7 Equipment Setup 38 Installing the Integrated 2S Cabinet Unit Syrup Line and Pump Harness Cable 38 Filling the Sanitizer Tank 43 EQUIPMENT SETUP Conti...

Page 4: ...ul interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...

Page 5: ...highest standard of sanitation When your equipment is delivered or if it has been unused for more than 24 hours follow the DAILY OPENING PROCEDURES in your standard operations manual s NOTE PARTS AND...

Page 6: ...dren aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use...

Page 7: ...6 PAGE INTENTIONALLY LEFT BLANK...

Page 8: ...80SS systems 4 MIS 3196 STAINLESS TUBE CABLE CASING ASSEMBLY 1 Attaches the flavor lines and or cables to the side of the freezer 5 SAN 756 SANITIZER TANK ASSEMBLY 1 Houses sanitizer cleaning solution...

Page 9: ...stems 0 for 80BLD 80BEV 80SS systems 14 SYR 946 SYRUP BAG LOCK 8 0 FOR SS BLD SYSTEMS Secures the syrup bag adapters to the bag fitments 8 for 80SS 80BLD systems 0 for 80BEV 80FCB systems The Integrat...

Page 10: ...9 PAGE INTENTIONALLY LEFT BLANK...

Page 11: ...11 12 14 OR BEV FCB SYSTEMS SS BLD SYSTEMS SS AND BLD SYSTEMS SS AND BLD SYSTEMS 13 1 13 2 13 3 13 4 BEV SYSTEMS BLD SYSTEMS SS SYSTEMS FCB SYSTEMS OR OR OR 26000 7 1 7 2 3 1 3 3 3 2 3 4 SS SYSTEMS B...

Page 12: ...s syrup from bags to pumps 8 for 80BEV 80FCB systems 0 for 80SS 80BLD systems 11 MIS 3026 SURFACE RACEWAY 1 Secures 9 tube assembly to the inside of the cabinet 12 1 MIS 3028 80M 1 SANITIZER FLUSH TUB...

Page 13: ...the C20600 WKN short mobile cart These carts include modified front and rear panels required for the installation of the Integrated 2S systems If you have a C206 cart that does not have modified front...

Page 14: ...13 PAGE INTENTIONALLY LEFT BLANK...

Page 15: ...e 2 Figure 2 7 1 2 4 8 9 3 8 10 1 10 2 6 5 11 12 1 12 2 13 T 12 3 OR OR OR BEV MODELS SS BLD MODELS FCB MODELS BEV FCB SYSTEMS SS BLD SYSTEMS See Figure 7 Electronics Parts and Connections 17 2 17 1 1...

Page 16: ...SPRING 1 ea Provides tension between tube connectors 3E INJ 116 LINE COUPLER NUT BLACK 1 ea Attaches flavor tubes to flavor manifold 3F SYR 901 6 9 TUBE ASSEMBLY TUBES 9 ea Brings syrup from pump to...

Page 17: ...o secure adapter to freezer door 10B ADPT 8750 CROWN ADAPTER WITOUT O RINGS 1 ea Attaches Injector Assembly to freezer door 10C RUB 632 INJECTOR ADAPTER O RING 1 ea Creates tension to secure adapter t...

Page 18: ...ea Provides sealed cavity inside syrup port 3 INJ 321C GEAR CARTRIDGE ASSEMBLY 1 Rotates product for even syrup distribution 4 SYR 932 6 9 TUBE ASSEMBLY 1 Supplies syrup to Blending Head from pumps 4...

Page 19: ...ing and base brackets 10 INJ 330 TSC BLENDING MOTOR ASSEMBLY HIGH RPM 1 Powers Blending system 11 INJ 331 BLENDING GEARBOX ASSEMBLY 1 Gears turn Gear Cartridge for even syrup distribution 11A FAS 2023...

Page 20: ...CTOR O RINGS 1 ea Provides extra tension between tube connectors 3D ROT 515 A 9 TUBE ASSEMBLY WAVE SPRING 1 ea Provides tension between tube connectors 3E INJ 116 LINE COUPLER NUT BLACK 1 ea Attaches...

Page 21: ...TING BRACKET KNOB 1 ea Secures base Mounting Bracket to Gear Box 10 ADPT 104R A CROWN ADAPTER WITH O RINGS 1 Attaches Blending Assembly to freezer door 10A RUB 627 TAYLOR ADAPTER O RING 8750 1 ea Crea...

Page 22: ...ly 3C FAS 2024 8 32 X M SCREW P H SS 1 ea Remains as a stationary screw 4 SYR 932 6 9 TUBE ASSEMBLY 1 Supplies syrup to the draw spout from the pumps 4A FAS 2051 ROLLED FLANGE EYELET 18 ea Provides te...

Page 23: ...22 FCB Door Spout Assembly and Related Parts Figure 3D 3A 3B 3C 2A 2 4H 4 4B 4G 4E 4D 4B 4F 4A 4A 4C 5 6 7 8 1 3 1B 1A D FOR FCB SYSTEMS 26003D...

Page 24: ...O 3 16 OD REDUCING UNION 1 ea Connects syrup pump to flavor line out 2 SYR 944 SYRUP TUBE ASSEMBLY SOFT SERVE 1 ea Transports flavor from bag to pump 2A FIX 1054 1 4 ID HOSE BARB SHUTOFF 1 ea Connects...

Page 25: ...tment 1D FIX 1035 1 4 TO 3 16 OD REDUCING UNION 1 ea Connects syrup pump to flavor line out 1E FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects bag connector assembly to flavor line pump 2 SYR 944SH S...

Page 26: ...r 80SS 80BLD 80BEV systems 1 2 MIS 3028S SANITIZER FLUSH TUBE ASSEMBLY BEVERAGE 1 ea Flushes flavor lines with sanitizer when attached 1B FIX 1051 SANITIZER TANK FITMENT 1 ea Connects flush tube to so...

Page 27: ...zer Pump and Related Parts Continued Figure 5 1C 1C 1D 1 1 1 2 OR OR 3 2 6 7 11 9 10 9 6 5 1B 1 2 1 3 8 1C 1A 1B 6 TO 9 TUBE LEAD TO SANITIZER TANK 4 BEV MODELS SS BLD MODELS FCB MODELS 26005 TO SANIT...

Page 28: ...ED CHANNEL 1 ea Covers and protects the cables and tubes of the Casing Assembly 3B MIS 3051 CH 6 CHANNEL MAGNET ASSEMBLY 2 ea Holds the Casing Channel to freezer panel 3C FAS 2040 6 32 x 1 4 PAN HEAD...

Page 29: ...28 Syrup Tray Sanitizer Tank 9 Tube Assembly Lead and Casing Figure 6 4 4B 4E 4C 4F 4G 4A 4D 4H 4H 4H 3C 3B 3A 3D 3E 2 26008 3 TO PUMPS 1B 1C 1D 1F 1E 1A 1...

Page 30: ...ea Secures the connection between screw and plate 2J FAS 2173 FLAT WASHER 18 8 S S 2 ea Secures the connection between bolt and nut 3 MIS 3220 TOUCH PANEL SIDE MOUNTING BRACKET ASSEMBLY 1 0 FOR BEV FC...

Page 31: ...1 for 80SS 80BEV 80BLD systems 0 for 80FCB systems 14 1 INJ 330TS INJECTOR MOTOR ASSEMBLY 1 0 FOR SS BEV SYSTEMS Supplies power to Motor to turns gears 1 for 80SS 80BEV systems 0 for 80FCB 80BLD syste...

Page 32: ...Taylor C206000 WFB mobile cart and the C20600 WKN short mobile cart These carts include modified front and rear panels required for the installation of the Integrated 2S systems If you have a C206 car...

Page 33: ...c Parts and Connections Figure 7 26006 10 7 17 11 19 27 21 23 22 19 20 26 28 18 12 7 25 9 6 7 8 T 17 16 22 24 13 14 2 14 1 5A 5 4 3 3E 3E 3C 3C 3G 3A 3F 3H 3F 3F 3B 3I 2 2C 2A 2F 2B 2G 2G 2H 2J 2E 2I...

Page 34: ...ER ADAPTER O RING FOR ADPT 101A ADAPTER 1 Creates tension to secure Adapter to freezer door 7 RUB 602 9 POS TUBE CONN GASKET 1 Provides sealed cavity 8 RUB 652 RSS SMALLER SYRUP PORT O RING 1 Provides...

Page 35: ...6 RUB 642 UPPER ADAPTER O RING FOR ADPT 101A ADAPTER 1 Creates tension to secure Adapter to spout 7 RUB 602 9 POS TUBE CONN GASKET 1 Provides sealed cavity 8 RUB 652 RSS SMALLER SYRUP PORT O RING 1 Pr...

Page 36: ...ADPT 104R A 1 Creates tension to secure adapter to freezer door 8 RUB 602 9 POS TUBE CONN GASKET 1 Provides sealed cavity 9 INJ 201A SYRUP MANIFOLD 1 Connects flavor line to blending head 10 MIS 3112...

Page 37: ...PORT O RING 1 Provides a sealed cavity inside the syrup port 5 RUB 652 RSS SMALLER SYRUP PORT O RING 1 Provides a sealed cavity inside the syrup port 6 INJ 117 TUBE CONNECTOR BODY BLACK 1 Secures fla...

Page 38: ...37 PAGE INTENTIONALLY LEFT BLANK...

Page 39: ...g Installing the Spout Assembly Mounting the Casing Assemblies Installing the Integrated 2S Cabinet Unit Syrup Line and Pump Harness Cable The integrated cabinet is designed to be installed inside the...

Page 40: ...he back of the Taylor cart or hanging over a little bit Ensure the 9 Tube Lead sanitizer line and pump harness cable hang down outside the cart 7 Check all tube and wiring connections and secure them...

Page 41: ...THE SHELF IF THE CONNECTION BECOMES LOOSE OR IF THE SEAL BECOMES WORN OVER TIME LEAKAGE COULD OCCUR AND COME IN CONTACT WITH THE PUMP CABLE CONNECTIONS THIS MAY RESULT IN ELECTRICAL SHOCK AND DAMAGE...

Page 42: ...e placed comfortably inside the cabinet corner Ensure the tubes do not bend sharply above or below the casing 23 Locate the electronic accessories plate Find the power entrance module connector with t...

Page 43: ...se the slot closest to the side of the freezer the 9 Tube Assembly is installed 28 Pull open the plastic grommet and place it around the 9 Tube Assembly tubes Snap the grommet into the hole on the mod...

Page 44: ...and may not clear the system of all bacteria present See the sanitizer manufacturer s information for potency and longevity Replace older solution with fresh solution when necessary Additionally use h...

Page 45: ...P Power Connections and Power Up Installing Flavors and Priming Syrup Lines Color Touch Panel Overview Consult your standard manual for important information and instructions on these topics Daily Ope...

Page 46: ...________________________ 4 Maximum Fuse Size __________________________ Amps 5 Minimum Wire Ampacity _______________________ Amps Flavor Burst is a registered trademark of the Flavor Burst Company Tay...

Reviews: