![Flavel RENOIR Installation And Maintenance Instructions Manual Download Page 3](http://html1.mh-extra.com/html/flavel/renoir/renoir_installation-and-maintenance-instructions-manual_2303360003.webp)
APPLIANCE DATA
Main injector (1 off)
Bray Elbow size 360, Cat 82
Pilot Type.
Copreci Single Flame
Type
21100 / 161
Max. Gross Heat Input :
6.0 kW
Min. Gross Heat Input :
1.8 kW
Cold Pressure :
20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition :
Rotary piezo, integral to gas valve
Electrode Spark Gap :
4.0 mm
Weight (Packed) :
25.0kg
Firebox Dimensions (with case fitted)
Width : (with fender fitted)
685mm
Height : (with feet fitted)
700mm
Depth : (with fender fitted)
325mm
Height to top of the flue spigot : 490mm (with feet fitted)
Gas Connection :
8mm compression
(Supplied with fire)
EFFICIENCY DECLARATION
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2002 and the result is 70%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by
Advantica.
The efficiency value may be used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of dwellings.
3