35
To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on the
appliance. When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as “RCF waste”. RCF waste is classed as a “stable”, non
reactive hazardous waste and may be disposed of at a landfill licensed to
accept such waste Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.
USER REPLACEABLE PARTS
The only user replaceable parts on this fire are the fuelbed components and
coals or pebbles which may be replaced as described in the above section. Replacement of any other
parts must be carried out by a competent person such as a CORGI registered gas installer. The part
numbers of the user replaceable parts are as follows, these are available from CFM Europe Ltd. who may
be contacted at the number on the rear cover of this book.
Complete Coal Pack
B-91480
Complete Pebble Pack
B-91520
Coal Fuelbed Matrix
B-91500
Pebble Fuel-bed Matrix
B-91540
Coal Fuelbed Front Rail
B-91490
Pebble Fuelbed Front Rail
B-91530
Loose Coal Pack
B-91510
Loose Pebble Pack
B-91550
Due to our policy of continual improvement and development the exact
accuracy of descriptions and illustrations cannot be guaranteed.
Part no. B-90710
Issue 2
CFM Europe Ltd.
Trentham Lakes
Stoke-on-Trent
Staffordshire
ST4 4TJ
Telephone - General Enquiries :
(01782) 339000
Telephone - Service :
(08700) 101187