Flavel Curve FCRR Series User Instructions Download Page 8

CLEANING - WARNING

Before attempting any cleaning operation ensure that the fire has been allowed to

fully cool.

CLEANING THE STAINLESS STEEL AND PAINTED METAL PARTS

The “Curve” fascia that was supplied with this product must only be cleaned with a

clean, damp cloth.

Abrasive cleaners, chemical cleaning agents or any type of polish must

never be used as damage to the finish may result.

CLEANING THE RIBBED FIBRE BACK

We do not recommend cleaning of the ribbed ceramic fibre back as this is a fragile

item and damage may result.

None of these parts must be washed or exposed to any cleaning agents or

water

.

Any damaged parts must be replaced by contacting your dealer or telephoning

BFM Europe Ltd. on the number stated on the rear cover of this book. The

ribbed ceramic fibre back must only be replaced with a complete and genuine item

and the fire must never be run with a damaged item in position.

The ceramic fibre back used in this product is manuafctured from R.C.F

(Refractory Ceramic Fibre) To ensure that the release of fibres from this item

is kept to a minimum, during installation and servicing we recommend that

you use a HEPA filtered vacuum to remove any dust accumulated in and

around the appliance before and after working on the appliance. When

replacing these articles we recommend that the replaced items are not

broken up, but are sealed within heavy duty polythene bags, clearly labelled

as “RCF waste”. RCF waste is classed as a “stable”, non reactive

hazardous waste and may be disposed of at a landfill licensed to accept

such waste Protective clothing is not required when handling these

articles, but we recommend you follow the normal hygiene rules of not

smoking, eating or drinking in the work area, and always wash your hands

before eating or drinking.

8

Summary of Contents for Curve FCRR Series

Page 1: ...Curve RADIANT FLAME EFFECT GAS FIRE User Instructions Model No s FCRR RN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E NB refers to fascia variant...

Page 2: ...ance above the fire is increased by 15mm for each 25mm of additional overhang in excess of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B Wh...

Page 3: ...iced at least once a year by a CORGI registered gas installer in G B and that during the service the fire is removed from the fire opening and the flue pipe visually checked for debris or blockages wh...

Page 4: ...described in the previous section In the event of repeated operation a CORGI registered gas installer must be called to investigate and rectify the cause REMOVAL OF THE CONTROLS COVER The controls cov...

Page 5: ...sc set in the MAN position d Switch the main valve knob to the OFF position Image above shows MAIN VALVE knob set in the OFF position e Press and hold the STAR button and UP button on the remote hand...

Page 6: ...handset twice NOTE The flame will go to HIGH rate heat input before going to designated LOW rate heat input To return back to HIGH rate heat input press the LARGE flame button twice To put the fire in...

Page 7: ...ounting brackets as shown in Fig 5 below then securing with two screws on the bottom face of the trim as shown in Fig 6 below Fig 5 Fig 6 7 Align mounting bracket on Curve fascia with mounting bracket...

Page 8: ...ly be replaced with a complete and genuine item and the fire must never be run with a damaged item in position The ceramic fibre back used in this product is manuafctured from R C F Refractory Ceramic...

Page 9: ...engineer Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed Part No B 106080 Issue 3 BFM Europe Ltd Trentham Lakes Sto...

Reviews: