Flavel Curve FCRR Series User Instructions Download Page 5

OPERATING THE FIRE USING THE REMOTE CONTROL HANDSET

a)

The control valve is positioned on the left hand side of the fire when

viewed from the front. Remove the controls cover as shown on

previous page

b)

To operate the appliance automatically via the remote control handset,

ensure that the on / off switch is switched to the “on” position as shown

below in Fig. 3

Fig. 3

c)

Switch the MANUAL control disc to the “ON” position. (Image above

shows “MANUAL” control disc set in the “MAN” position).

d)

Switch the main valve knob to the “OFF” position. (Image above shows

“MAIN VALVE” knob set in the “OFF” position.

e)

Press and hold the “STAR” button and “UP” button on the remote hand

set simultaneously, see Fig. 4 overpage for image of handset.

f)

The valve will then emit an audible beep and commence its ignition

sequence. When the pilot flame has been established, the control will

continue to beep whilst the thermocouple heats up. When the

thermocouple has reached operating temperature, it will allow gas to

flow to the burner and the burner will light at high rate heat input

(6.5kW).

5

On / Off Switch

“MANUAL”

Control Disk

“MAIN VALVE” Knob

Summary of Contents for Curve FCRR Series

Page 1: ...Curve RADIANT FLAME EFFECT GAS FIRE User Instructions Model No s FCRR RN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E NB refers to fascia variant...

Page 2: ...ance above the fire is increased by 15mm for each 25mm of additional overhang in excess of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B Wh...

Page 3: ...iced at least once a year by a CORGI registered gas installer in G B and that during the service the fire is removed from the fire opening and the flue pipe visually checked for debris or blockages wh...

Page 4: ...described in the previous section In the event of repeated operation a CORGI registered gas installer must be called to investigate and rectify the cause REMOVAL OF THE CONTROLS COVER The controls cov...

Page 5: ...sc set in the MAN position d Switch the main valve knob to the OFF position Image above shows MAIN VALVE knob set in the OFF position e Press and hold the STAR button and UP button on the remote hand...

Page 6: ...handset twice NOTE The flame will go to HIGH rate heat input before going to designated LOW rate heat input To return back to HIGH rate heat input press the LARGE flame button twice To put the fire in...

Page 7: ...ounting brackets as shown in Fig 5 below then securing with two screws on the bottom face of the trim as shown in Fig 6 below Fig 5 Fig 6 7 Align mounting bracket on Curve fascia with mounting bracket...

Page 8: ...ly be replaced with a complete and genuine item and the fire must never be run with a damaged item in position The ceramic fibre back used in this product is manuafctured from R C F Refractory Ceramic...

Page 9: ...engineer Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed Part No B 106080 Issue 3 BFM Europe Ltd Trentham Lakes Sto...

Reviews: