SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Model
FPCL**RN
Gas Type
G20
Main injector (1 off)
Size 1.65mm
Pilot Type
S.I.T. Oxystop YA OP 9061
Max. Gross Heat Input :
5.0kW
Min. Gross Heat Input :
2.8kW
Cold Pressure :
20.0 +/-1.0 mbar
Ignition :
6V Battery Generator
Electrode Spark Gap
4.0mm
Weight
29.5kg
Firebox dimensions
Width :
(with fascia fitted)
750mm
Height : (with fascia fitted)
600mm
Depth :
(overall-with fascia)
223mm
Depth :
(from mounting face)
75mm
Gas Connection
8mm Compression
(Supplied with fire)
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 and the result is 71.2%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings.