![Flashcut CNC 401A Hardware Manual Download Page 10](http://html1.mh-extra.com/html/flashcut-cnc/401a/401a_hardware-manual_2303097010.webp)
FlashCut CNC
FlashCut CNC
Section
Section 2
2
Hardware Guide
Hardware Guide
6
6
BE VERY CAREFUL WHEN DOING ANY WIRING. IMPROPER
WIRING WILL DAMAGE THE MOTOR SIGNAL GENERATOR.
Two pins are directly connected to ground and +5V from the internal
power supply. These are provided for convenience as a source for the
optical ground and o5V if there is no external power source
available. Using the internal supply to power the optical isolators will
negate most of the isolation provided by the optical isolators. To use the
internal supply, directly connect DB-25 pin 24 to 25 and pin 22 to 23.
The motor signal lines as seen from the back of the box are arranged as
follows:
1
13
14
25
DB25
Pin
Signal
DB25
Pin
Signal
1
NC
14
ENABLE ALL
2
NC
15
θ
PARK
3
NC
16
Z PARK
4
NC
17
Y PARK
5
NC
18
X PARK
6
NC
19
θ
DIRECTION
7
NC
20
Z DIRECTION
8
NC
21
Y DIRECTION
9
X DIRECTION
22
Internal VCC +5V
10
θ
STEP
23
OPT VCC (INPUT)
11
Z STEP
24
Internal GND
12
Y STEP
25
OPT GND (INPUT)
13
X STEP
Turning off the Controller
Always turn off the motor signal generator when it is not in
use.