Manual control
To press enter then into the edit status. Press up or down to change channels value, press
enter again to choose tens place edit. Press enter again to choose ones place edit. Press enter
once more to exit edit.
System information
Advanced
Item
Instructions
Software edition
Current edition
DMX value
No. and percentage to show channels value
System wrong record
If red EPR light on show the light running wrongly, please enter
into sub interface to check. After check to press delete to clear
wrong record
Wrong information
Instructions
Motorse reset failure
Drive board no feedback,. The wires connected display board and
drive board problem, or check drive board problem.
X axis resett failure
X axis photoelectric switch problem, or X axis motors problem.
Y axis reset failure
Y axis photoelectric switch problem, or Y axis motors problem.
X axis Hall wrong
X axis Hall problem
Y axis Hall wrong
Y axis Hall problem
Color wheel reset
failure
Color wheel Hall problem or color wheel motor problem.
Gobo wheel reset
failure
Gobo wheel Hall problem or Gobo wheel motor problem.
Zoom reset failure
Zoom Hall problem, or zoom motor problem.
Led lamp control
failure
Turn on led lamp failure, led problem
Item
Instructions
Reset correction
After into sub interface, adjust X axis,Y axis waiting motors reset
place, to make up for errors, adjust range -128~+127, 0 indicate
no adjustment
Sensors monitor
Real time monitor photoelectric switchs and halls , sensors
status.
Password is
up up up down down down
. To verify press enter.