background image

LED PAR 64 19x10W RGBW 4in1 IP65 mk2 Alu Housing PowerCon True Sockets [P7110027] 

 

www.flash-butrym.pl 

5

 

 

Classic 8 [8CH] 

Channel 

Function 

Effect 

CH 1 

Dimmer 

0-255: 0-100% 

CH 2 

Strobe 

0-10: No Function 

11-255: Strobe 1-20Hz 

CH 3 

Red 

0-255: 0-100% 

CH 4 

Green 

0-255: 0-100% 

CH 5 

Blue 

0-255: 0-100% 

CH 6 

White 

0-255: 0-100% 

CH 7 

Color / Macro 

0-5:

 

no

 

function

 

6-10:

 

red

 

11-15:

 

green

 

16-20:

 

blue

 

21-25:

 

cyan

 

26-30:

 

magenta

 

31-35:

 

yellow

 

36-40:

 

light-red

 

41-45:

 

light-green

 

46-50:

 

light-blue

 

51-55:

 

orange

 

56-60:

 

mint

 

61-65:

 

sky

 

blue

 

66-70:

 

light-cyan

 

71-75:

 

light-magenta

 

76-80:

 

light-yellow

 

81-85:

 

white

 

86-90:

 

white 9000k

 

91-95:

 

white 6500k

 

96-100:

 

white 5600k

 

101-105:

 

white 5000k

 

106-110:

 

white 4500k

 

111-115:

 

white 3200k

 

116-120:

 

white 2500k

 

121-125:

 

white 2200k

 

126-130: macro 1 - step change:

 red-green-blue 

131-135: macro 2 - step change:

 red-green-blue-

-magenta-yellow-white 

cyan

136-140: macro 3 - step change:

 red-green-blue-

-magenta-yellow 

cyan

141-145: macro 4 - step change:

 red-magenta-blue-

-green-yellow 

cyan

146-150: macro 5 - fade:

 red-green-blue 

151-155: macro 6 - fade:

 red-green-blue-

-magenta-yellow-white 

cyan

156-160: macro 7 - fade:

 red-green-blue-

-magenta-yellow 

cyan

161-165: macro 8 - fade:

 red-magenta-blue-

-green-yellow 

cyan

166-170: macro 9 - fade:

 red-orange-yellow 

171-175: macro 10 - fade:

 red-violet-blue-magenta 

176-180: macro 11 - fade: 

green-

-blue-violet 

cyan

181-235: no function 

236-240: sound mode 1 - step change: 

red-green-blue

 

241-245: sound mode 2 - step change: 

red-green-blue-

-magenta-yellow-white

 

cyan

246-250: sound mode 3 - step change: 

red-green-blue-

-magenta-yellow

 

cyan

251-255: sound mode 4 - step change: 

red-magenta-blue-

-green-yellow

 

cyan

CH 8 

Speed 

if CH7 is set to 

6-125 

(color) 

0-5: no function 

6-255: pulse speed, fast to slow 

 

if CH7 is set to 

126-180 

(macro) 

0-255: macro speed, fast to slow

 

 

 

Summary of Contents for P7110027

Page 1: ...USER MANUAL INSTRUKCJA OBS UGI LED PAR 64 19x10W RGBW 4in1 IP65 mk2 Alu Housing PowerCon True Sockets P7110027...

Page 2: ...1 Voltage specification 4 5 2 Connecting power supply 4 6 Operation manual 4 6 1 Control panel 4 6 2 Master slave 4 6 3 DMX channel list 4 1 Wprowadzenie 8 2 Zasady bezpiecze stwa 8 3 Informacje o pro...

Page 3: ...he device is equipped with high quality bright LEDs while maintaining a small electric power consumption low operating temperature and long life Unique design high quality and high durability make thi...

Page 4: ...ackaging check if the device was not damaged during transport Before connecting to the mains make sure that the device is securely mounted The manufacturer is not responsible for damage caused by unst...

Page 5: ...of devices connected in series 12 6 OPERATION MANUAL 6 1 Control panel The control panel is equipped with LCD display and 4 control buttons with the following functions 1 ESC go back from the selecte...

Page 6: ...131 135 macro 2 step change red green blue magenta yellow white cyan 136 140 macro 3 step change red green blue magenta yellow cyan 141 145 macro 4 step change red magenta blue green yellow cyan 146 1...

Page 7: ...no Function 11 255 strobe 1 20Hz RGB 3CH Channel Function Effect CH 1 Red 0 255 0 100 CH 2 Green 0 255 0 100 CH 3 Blue 0 255 0 100 RGBW 4CH Channel Function Effect CH 1 Red 0 255 0 100 CH 2 Green 0 2...

Page 8: ...5600k 101 105 white 5000k 106 110 white 4500k 111 115 white 3200k 116 120 white 2500k 121 125 white 2200k 126 130 macro 1 step change red green blue 131 135 macro 2 step change red green blue magenta...

Page 9: ...z dze 3 INFORMACJE O PRODUKCIE Urz dzenie wyposa one jest w wysokiej jako ci jasne diody LED przy zachowaniu niewielkiego zu ycia energii elektrycznej niskiej temperatury pracy oraz du ej ywotno ci Wy...

Page 10: ...A Po wyj ciu urz dzenia z opakowania nale y sprawdzi czy nie zosta o ono uszkodzone podczas transportu Przed pod czeniem do sieci elektrycznej nale y upewni si e urz dzenie zamocowane jest stabilnie P...

Page 11: ...trami urz dzenia i nie zostaj przekroczone ograniczenia dotycz ce poboru energii elektrycznej z sieci UWAGA W przypadku uszkodzenia przewodu nie nale y dokonywa samodzielnej naprawy Wymiana lub napraw...

Page 12: ...wony 0 255 0 100 CH 4 Zielony 0 255 0 100 CH 5 Niebieski 0 255 0 100 CH 6 Bia y 0 255 0 100 CH 7 Kolor Macro 0 5 brak funkcji 6 10 Czerwony 11 15 Zielony 16 20 Niebieski 21 25 Cyan 26 30 Magenta 31 35...

Page 13: ...ci 6 125 kolor ustawionych w kanale 7 CH7 0 5 brak funkcji 6 255 pulsowanie szybko wolno Dla warto ci 126 180 macro ustawionych w kanale 7 CH7 0 255 pr dko efekt w Macro szybko wolno Pro 6 6CH Kana F...

Page 14: ...0 100 CH 6 Niebieski precyzyjnie 0 255 ustawienie precyzyjne 16 bit CH 7 Bia y 0 255 0 100 CH 8 Bia y precyzyjnie 0 255 ustawienie precyzyjne 16 bit Flash A DMX 8CH Channel Funkcja Efekt CH 1 Czerwon...

Page 15: ...a zmiana Czerwony Zielony Niebieski Magenta ty Cyan 161 165 Macro 8 p ynna zmiana Czerwony Magenta Niebieski Zielony ty Cyan 166 170 Macro 9 p ynna zmiana Czerwony Orange ty 171 175 Macro 10 p ynna zm...

Reviews: