www.flash-butrym.pl
6
6.2
Voltage specification
Input Voltage
Total Power
Frequency
100~245V
200W
50/60Hz
6.3
Connecting power supply
The connection is performed using power cable with PowerCon connector (included).
The device must be operated by qualified personnel. Make sure that the power grid supply parameters are
consistent with device parameters and limitations are not exceeded.
CAUTION!
In the case of cable damage do not attempt to repair. Replacement or repair can be made only
on the manufacturer or by a person with appropriate permissions.
7
OPERATION MANUAL
7.1
Control panel
The control panel is equipped with LCD display and 4 control buttons with the following functions:
1.
MENU – enter to main menu, go back from the selected options, cancel changes
2.
DOWN – choose option, edit parameter
3.
UP – choose option, edit parameter
4.
ENTER edit selected option, confirm changes
7.2
Menu
Menu diagram:
Change DMX Address
Address
(1-511)
→
edit address
ENTER
→
change value
UP/DOWN
exit
MENU/WAIT 5 SEC
save value
ENTER
cancel
MENU
Set manual dimmer
settings
Manual settings
(DIMMER)
→
edit settings
ENTER
→
change value
UP/DOWN
exit
MENU/WAIT 5 SEC
save and go to
next param.
ENTER
apply settings to
device
DISCONNECT DMX
SIGNAL, WAIT 3
SEC
cancel current
param. edit/back
MENU/WAIT 5 SEC
Turn on Sound Mode
Sound
(ON, OFF)
→
turn on
ENTER
→
turn off
ENTER/MENU