www.flash-butrym.pl
4
4
INSTALLATION
After removing the packaging, check if the device was not damaged during transport. Before connecting to
the mains, make sure that the device is securely mounted. The manufacturer is not responsible for damage
caused by unstable mounting.
Ensure proper connection to the mains and proper grounding. Make sure that the electrical parameters are
consistent with device requirements. All activities, including connecting the device to the mains must be
performed by qualified personnel.
This fixture may be mounted in any position provided there is adequate room for ventilation.
5
CONNECTIONS
The device is equipped with the following interfaces:
1.
DMX (in/out): XLR 3-pin socket
2.
Power (in/out): powerCON
5.1
Connecting DMX signal
The connection is performed using cable with XLR-female -> XLR-Male plugs.
To link fixtures together you must obtain data cables. If you choose to create your own cable please use data-
grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard
microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following
characteristics:
2-conductor twisted pair plus a shield.
maximum capacitance between conductors-30 pF/ft.
maximum capacitance between conductor and shield -55pF/ft.
maximum resistance of 20 ohms/1000ft.
nominal impedance 100-140 ohms.
Maximum recommended serial data link distance: 500 meters(1640ft).
Maximum recommended number of fixtures on a serial data link: 32 fixtures.