background image

 Please keep this User Manual for future 

consultation.  If  you  sell  the  fixture  to 

another user, be sure that they also receive 

this instruction booklet.

 Unpack and check carefully there is no 

transportation damage before using the 

fixture.

 Before operating, ensure that the voltage 

and frequency of power supply match the 

power requirements of the fixture.

 It’s important to ground the yellow/green 

conductor to earth in order to avoid electric 

shock.

 Disconnect main power before servicing 

and maintenance.

 Use safety chain when fixes this fixture. 

Don’t handle the fixture by taking its head 

only, but always by taking its base.

 Maximum ambient temperature is: 400C

 

IMPORTANT!

 

Do not point strong light output from other fixtures 

at the 

LED PAR

, as intense illumination can 

damaged the display.

Don’t operate it where the temperature is 

higher than this.

 In the event of serious operating problem, 

stop  using  the  fixture  immediately.  Never 

try to repair the fixture by yourself. Repairs 

carried out by unskilled people can lead to 

damage or malfunction. Please contact the 

nearest authorized technical assistance 

center. Always use the same type spare 

parts.

 Do not connect the device to any dimmer 

pack.

 Do not touch any wire during operation 

and there might be a hazard of electric 

shock.

 To prevent or reduce the risk of electrical 

shock or fire, do not expose the fixture to 

rain or moisture.

 The housing must be replaced if they are 

visibly damaged.

 Do not look directly at the LED light spot 

while the fixture is on.

2. SAFETY INFORMATION

1. INTRODUCTION

THANK YOU FOR PURCHASING 

LED PAR 36 12xUV

. FOR SAFETY REASONS AND TO 

ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.

W A R N I N G !

User Manual 

Instrukcja Obsługi

Figure 2.

 Lenses can focused sunlight and strong light, presenting a risk of fire and damage to the fixture. 

 

Shield or shade the head if necessary.

Summary of Contents for F7100328

Page 1: ...User Manual Instrukcja Obsługi F7100328 LED PAR 36 12xUV ...

Page 2: ...is higher than this Intheeventofseriousoperatingproblem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and ...

Page 3: ... be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it The device is equipped with the following interfaces 1 DMX in out XLR 3 5 pin socket 2 Power in out powerCON socket 1 3 2 2 FEMALE XLR GROUND DMX DMX MALE XLR 3 1 CAUTION At the last fixture the DMX signal has to be terminated with a terminator Solder a 120Ω resistor be...

Page 4: ...r or by a person with appropriate permissions Make sure that the power grid supply parameters are consistent with device parameters and limitations are not exceeded Using lamp the change rate of power voltage should be within 10 if the voltage is too high it will shorten the light s life if it s not enough the lamp will be dark Please restart it after turning off light for 20 minutes until full co...

Page 5: ... Press ENTER to turn the below value A3 01 A3 32 Adjust hopping speed slow to fast Sound Active Mode A4 01 A4 19 Press ENTER to turn the below value Select sound active program A4 01 A4 04 Adjust sound activated sensitivity Strobe Mode A5 01 A5 19 Press ENTER to turn the below value Select the LED position A5 01 A5 32 Adjust strobe speed slow to fast Static Color Dimmer r000 255 Adjust the brightn...

Page 6: ...onić głowę User Manual Instrukcja Obsługi CH Function Value Description 1 No Function 0 10 Static Color 11 50 CH2 to Select LED Position Auto Play 51 100 CH3 to Adjust Speed Fade 101 150 CH2 to Select LED Position CH3 to Adjust Speed Sound Active 151 200 Strobe 201 255 CH2 to Select LED Position CH3 to Adjust Speed 2 Different LED Position 0 255 3 Speed Adjustment 0 255 Slow to Fast 4 Dimmer for 5...

Page 7: ...ządzenie powinno być zainstalowane w dobrze wentylowanym pomieszczeniu w odległości co najmniej 15cm od najbliższej powierzchni ściany sufitu itp Jednocześnie należy upewnić się że otwory wentylacyjne nie są zatkane oraz wentylatory działają poprawnie Po wyjęciu urządzenia z opakowania należy sprawdzić czy nie zostało ono uszkodzone podczas transportu Przed podłączeniem do sieci elektrycznej należ...

Page 8: ...ię przy użyciu przewodu zakończonego z jednej strony wtyczką sieci elektrycznej i wtyczką typu powerCON z drugiej strony w zestawie Urządzenie musi być obsługiwane przez UWAGA W przypadku uszkodzenia przewodu nie należy dokonywać samodzielnejnaprawy Wymianalubnaprawamożebyćwykonanajedynie w serwisie producenta lub przez osobę z odpowiednimi uprawnieniami wykwalifikowany personel techniczny Należy ...

Page 9: ... slow to fast Fade Mode A3 01 A3 19 Press ENTER to turn the below value A3 01 A3 32 Adjust hopping speed slow to fast Sound Active Mode A4 01 A4 19 Press ENTER to turn the below value Select sound active program A4 01 A4 04 Adjust sound activated sensitivity Strobe Mode A5 01 A5 19 Press ENTER to turn the below value Select the LED position A5 01 A5 32 Adjust strobe speed slow to fast Static Color...

Page 10: ... 150 CH2 to Select LED Position CH3 to Adjust Speed Sound Active 151 200 Strobe 201 255 CH2 to Select LED Position CH3 to Adjust Speed 2 Different LED Position 0 255 3 Speed Adjustment 0 255 Slow to Fast 4 Dimmer for 5 7 CH 0 255 0 100 5 Position 1 0 255 6 Position 2 0 255 7 Position 3 0 255 8 Position 4 0 255 User Manual Instrukcja Obsługi ...

Page 11: ...LED PAR 36 12xUV Art No F7100328 ...

Page 12: ...www flash butrym pl F7100328 ...

Reviews: