Installation items:

 The factory only provides the  main unit and the water unit; the other items in the illustration 

are necessary spare parts for the water system ,that provided by users or the installer.

     

 3.1 Installation illustration

Attention:

Please follow these steps when using for the first time

1.Open valve and charge water.

2.Make sure that the pump and the water-in pipe have been filled with water.

3.Close the valve and start the unit.

 

 

3.INSTALLATION AND CONNECTION

4

Chlorinator cell

Water outle t

Pool

Valve

Water 

supply

Water inlet

Water pump

     Sand fil ter

(or other type fil ter)

4.3 How to choose Mode

Cooling mode

Heating mode

◎ Press “ M ” to choose mode(mode can be changed under running)
◎ Press “    ” to power on unit. Under running, the LCD displays the water setting temp, 
    water-out temp and current mode.
◎ Press       ” to set temp. 1 degree higher, press        ” to set temp. 1 degree lower.

4.4 How to know the current status?

Water 

outlet

temp. 

Ambient

 temp.

compressor 
exhaust temp.

Condenser

  temp.

Under running, press        3s to check the current status of the 

unit. You can check water-out/ambient/compressor/condenser

temperature. If no buttons are depressed within  10 seconds, 

the LCD will display water-setting/water-out temp.

When the unit is switched off, current water-out temperature 

is displayed.

M

4. USAGE AND OPERATION

9

AUX

parameter 9

Mode: 0(heating only)

 

            1(

cooling and heating)

            2(heating only)
factory setting: 1

 

parameter

08

automatic restarting (0/1)
factory setting: 1

water pump mode:
0: already open
1: 30s start before compressor start
    30s stop after compressor stop.

parameter

7

TEMP

SET

 

TEMP

SET

 

Con ne ct to po wer  sup pl y

Summary of Contents for KP-017

Page 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...

Page 2: ...ol Heat Pumps Plumbing 6 3 5 Swimming Pool Heat Pumps Electrical Wiring 7 3 6 Initial Start up of the Unit 7 4 Usage and Operation 8 4 1 The Functions of the LCD Controller 8 4 2 How to Set Operation Parameter 8 4 3 To Choose Mode 9 4 4 How to know the Current Status 9 4 5 Operation Data Setting 10 5 Maintenance and Inspection 11 5 1 Maintenance 11 5 2 Trouble Shooting Guide 11 6 Appendix 12 6 1 C...

Page 3: ...ool Heat Pump Unit heats the swimming pool water and keeps the temperature constant This type of pump has the following characteristics 1 Durable The heat exchanger is made of PVC titanium tube which can withstand prolonged exposure to corrosives such as chlorine 2 Installation flexibility The unit can be installed outdoors or indoors 3 Quiet operation The unit comprises an effi cient rotary scrol...

Page 4: ...ion Compre sso r motor solenoid valve four way valve capacit or condenser heater or electri cal cable are defecti ve Ambient temp Sensor failure The sensor is open or short circuit Check or change the sensor The sensor is open or short circuit Check or change the sensor The sensor is open or short circuit Check or change the sensor Compressor over current Compressor is over load Check the electric...

Page 5: ...s open 1 30 seconds start before compressors starting 30 seconds stop after compressors stopping water pump stops when water temperature setting temperature factory setting 0 20 45 7 15 F0 150min 3min 95 7 1 1 1 4 4 Operation data setting 2 SPECIFICATION 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 40 41 42 30 10 20 31 1 Front panel 15 Power cor d...

Page 6: ... power on unit Under running the LCD displays the water setting temp water out temp and current mode Press to set temp 1 degree higher press to set temp 1 degree lower 4 4 How to know the current status Water outlet temp Ambient temp compressor exhaust temp M M M Condenser temp Under running press 3s to check the current status of the unit You can check water out ambient compressor condenser tempe...

Page 7: ...ool filter piping The unit may be installed virtually anywhere outdoors For indoor pools consult the supplier Unlike a gas heater it has no draft or pilot light problem in a windy area DO NOT place the unit in an enclosed area with a limited air volume where the units discharge air will be re circulated DO NOT place the unit to shrubs which can block air inlet These locations deny the unit of a co...

Page 8: ...gh the conduit nipple and wire nut the electric supply wires to the three connections already in the junction box four connections if three phase To complete electrical hookup connect Heat Pump by electrical conduit UF cable or other suitable means as specified as permitted by local electrical authorities to a dedicated AC power supply branch circuit equipped with the proper circuit breaker discon...

Reviews: