INSTALLATION OF THE FIRE 

Where a chimney is not blocked off completely it will cause the heater to cut out during use. If you are not sure that you have cut off the draw 

100% from the chimney, we recommend covering the five banks of slots in the rear of the case and each bank at the top either side.

 

 

Electrical connections 
Your appliance comes fitted with a plug that incorporates a 13A fuse. The replacement fuses must be 13A and ASTA approved. If the fuse cover is 
lost the plug must not be used until a replacement cover, of the same colour, is obtained from an electrical retailer. 
The appliance is fitted with a moulded plug, if it is necessary to cut off the plug for any reason, it must be discarded immediately with the 
fuse removed. Under no circumstances should any attempt be made to reuse the plug, do not insert into any 13A socket as this could cause 
a hazard. If the mains cable is damaged it must be replaced by the manufacturer or an authorised technical service centre. 

 

WARNING THIS APPLIANCE MUST BE EARTHED 

IMPORTANT 

The wires in the mains lead are coloured in accordance with the following code. 

 

Green and yellow: 

EARTH 

Blue: 

NEUTRAL 

Red: 

LIVE 

As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings in your plug proceed as follows: - 

 

The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E, or 
coloured green or coloured green and yellow, or marked with the earth symbol 

 

The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N, or coloured 
black. 

 

The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L, or coloured 
red. 

 

Important: The fire must be positioned so that the plug socket is accessible once the fire has been installed. In the unlikely event of 

breakdown access must be allowed for so that the fire may be serviced (DO NOT SEAL). This will involve the fire being removed from the wall in 
order to gain access to the rear. The mains cable must therefore be long enough to allow this. If the removal of the plug is absolutely necessary 
for installation, cut off in an area within 100mm only of the plug itself.   Any further will affect your warranty. Where an inset fire is being used

 

in an existing chimney, it is important that the chimney is blocked off to prevent airflow problems with the fire.

 

 

Using as a hole in the Wall: 
The inset hole dimensions for the fire are: depth 10cm, height 52cm and width 93cm. To prevent the fire from being pulled out it must be secured 
into place. The height at which you may wish to fix the fire into the wall is up to you, though we recommend anywhere from 40-60cm from the 
floor to the bottom of the fire. The two wall brackets should be fixed with the highest point of the edge facing forward/upward either side of the 
inset hole Fig.1. Corresponding brackets can be found fixed to the back of the fire.  Once the wall brackets have been fixed in place, lift and hook 
the fire onto them. A second bar should then be added to the underside of the fire Fig.3. A channel in the underside of the fire will be visible, the 
remaining bracket will slot into this. Again mark off, remove fire and fit the bracket to the wall. Refit the fire lift and hook onto the brackets. See 
fuel effect before fitting the glass. 

 

Using as a Hang on the Wall. 
The height at which you may wish to fix the fire to the wall is up to you, though we recommend anywhere from 40-60cm from the floor to the 
bottom of the fire. The wall bracket should be fixed to the wall with the highest point of the edge facing forward/upward Fig.2. The corresponding 
edge where the fire is to be hung on the wall bracket can be found on the back, at the top, across the fires centre. Once the wall bracket has been 
fixed, lift and hook the fire into place. A second bar should then be added to the underside of the fire Fig.3. A channel in the underside of the fire 
will be visible, the remaining bracket will slot into this. Again mark off, remove fire and fit the bracket to the wall. Refit the fire, lift and hook onto 
the brackets. See fuel effect before fitting the glass. 