![Flamerite Fires Ador Installation, Precautions & Servicing Download Page 9](http://html1.mh-extra.com/html/flamerite-fires/ador/ador_installation-precautions-and-servicing_2302458009.webp)
9 |
P a g e
•
No power to the fire:
Check the wall socket, plug, fuse and lamps.
•
Heat turns off quickly after turn on:
Set thermostat on app after turning heat on, not before.
•
No illumination:
Make sure fire is turned on. Check heater is working, if so check lamps.
•
Heater blowing cold air:
The safety cut out may have operated. Check for obstruction around the
heater. If continually a problem and fitted into a cavity wall or chimney breast check with installer the
inset opening has been 100% fully sealed from drawn air and draft.
•
Noise when illuminated:
Due to moving parts, the electric fire will make a noise.
•
Noise from the heater when in use:
The sound of rushing air is normal.
Information requirement for electric local space heaters
Model identifier (s)
Ador
Luma 900
Luma
1200
Jaeger
1020
Item
Symbol
Value
Value
Value
Value
Unit
Heat
output
Nominal heat output
Pnom
2
2
2
1.5
kW
Minimum heat output (indicative)
Pmin
1
1
1
0.75
kW
Maximum continuous heat output
Pmax,c
2
2
2
1.5
kW
Auxiliary electricity consumption
At nominal heat
elmax
35
43
43
48
W
At minimum heat
elmin
35
43
43
48
W
Instandby
elSB
.5
.5
.5
.5
W
Type of heat output/room temperature control
With distance control option
Room temperature control, with open window detection
Adaptive Start
Yes
With electronic room temperature control plus week timer
Yes
Contact details:
Flamerite Fires Ltd. Greenhough Road, Lichfield. Staffs.
WS137AU
Trouble Shooting
Information Requirements