Flamerite Fires Ador Installation, Precautions & Servicing Download Page 9

9 | 

P a g e

 

 

 

 

 

 

 

 

 

 

No power to the fire:

 Check the wall socket, plug, fuse and lamps. 

 

Heat turns off quickly after turn on:

 Set thermostat on app after turning heat on, not before. 

 

No illumination:

 Make sure fire is turned on.  Check heater is working, if so check lamps.   

 

Heater blowing cold air:

 The safety cut out may have operated. Check for obstruction around the 

heater.  If continually a problem and fitted into a cavity wall or chimney breast check with installer the 

inset opening has been 100% fully sealed from drawn air and draft. 

 

Noise when illuminated:

 Due to moving parts, the electric fire will make a noise.  

 

 

Noise from the heater when in use:

 The sound of rushing air is normal. 

 

 

 

 

 

 

 

Information requirement for electric local space heaters 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model identifier (s)  

  

  

  

Ador 

Luma 900 

Luma 

1200 

Jaeger 

1020 

  

 

 

Item 

  

  

  

Symbol 

Value 

Value 

Value 

Value 

Unit 

 

 

Heat 

output 

  

  

  

  

  

  

  

  

  

 

 

Nominal heat output 

 

 

Pnom 

1.5 

kW 

 

 

Minimum heat output (indicative) 

 

Pmin 

0.75 

kW 

 

 

Maximum continuous heat output 

 

Pmax,c 

1.5 

kW 

 

 

Auxiliary electricity consumption 

  

  

  

  

  

  

  

 

 

At nominal heat 

 

 

elmax 

35 

43 

43 

48 

 

 

At minimum heat 

 

 

elmin 

35 

43 

43 

48 

 

 

Instandby   

 

 

elSB 

.5 

.5 

.5 

.5 

 

 

Type of heat output/room temperature control 

  

  

  

  

  

  

 

 

With distance control option 

 

 

 

 

 

 

  

 

 

Room temperature control, with open window detection 

 

 

 

 

  

 

 

Adaptive Start 

 

 

 

 

 

 

 

Yes  

 

 

With electronic room temperature control plus week timer 

  

  

  

Yes 

 

 

Contact details:  

Flamerite Fires Ltd. Greenhough Road, Lichfield.  Staffs. 

 

 

  

 

 

  

  

WS137AU   

 

 

 

 

 

  

 

 

  

  

  

  

  

  

  

  

  

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble Shooting 

 

 

 

 

 

 

Information Requirements 

 

 

 

 

 

 

Summary of Contents for Ador

Page 1: ...efore removal from the packaging and installation Consider if help is required Always read this manual first before attempting to install or use and keep in a safe place Any alteration to the power ca...

Page 2: ...regulate and clean the appliance or perform user maintenance Some parts of this product can become very hot and cause burns Particular attention must be given where children and vulnerable people are...

Page 3: ...lug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or coloured green or coloured green and yellow or mar...

Page 4: ...found on the back at the top and across the suites centre Once the top fixing rail is secured to the wall lift and hook the suite onto it The lower MDF rail should then be added to the underside of t...

Page 5: ...ot pictured The log effect must be positioned according to the images below The Jaeger 1360 uses OmniGlide tilting glass care are must be taken to ensure there is enough room between the front of the...

Page 6: ...6 P a g e Verada Large Cinder...

Page 7: ...heater allowed to cool Insert A Hold the glass panel in each bottom corner B Tilt the top of the glass into the fire C Place the bottom on the glass panel into the channel Adjust the glass panel for a...

Page 8: ...e 240V 6W 3000k E14 LED lamps Allow a suitable time for the lamps to cool then remove the glass fuel effect see Installation Remove the two screws from either side of the fuel bed and lift out of plac...

Page 9: ...ater when in use The sound of rushing air is normal Information requirement for electric local space heaters Model identifier s Ador Luma 900 Luma 1200 Jaeger 1020 Item Symbol Value Value Value Value...

Page 10: ...5 kW Auxiliary electricity consumption At nominal heat elmax 0 033 0 043 0 058 0 048 kW At minimum heat elmin 0 033 0 043 0 058 0 048 kW Instandby elSB 0 0005 0 0005 0 0005 0 0005 kW Type of heat out...

Reviews: