OUTLET DUCTING: 
 

Hitex heater duct with a minimum temperature handling of 
300 deg F including wire reinforcement to prevent collapsing. 
Heater is designed for use with 1 x 12” (FV-HD12) or 1 x 16” 
(FV-HDG16) diameter ducting equipped with pin lock or cuff 
& buckle provided on collar of ducting. Ducting should be 
inspected periodically for tearing and/or wear marks.  
Ducting should be stored in a dry area when not in use. 

INLET DUCTING: 
 

Inlet  ducting  can  be  used  on  the  return  air  inlet  of  heater. 
The heater is designed for 12” inlet diameter ducting with pin 
lock or cuff and buckle system.

 

 
MAINTENANCE: 
 
1.  Every construction heater should be inspected before each use, and at 

least  annually  by  a  qualified  service  person.  Incorrect  maintenance  my 
result  in  improper  operation  of  the  heater  and  serious  injury  could 
occur. 

 
2.  The  hose  assemblies  shall  be  visually  inspected  prior  to  each  use  of  the 

heater. If it is evident there is excessive abrasion or wear, or the hose is cut, it 
must  be  replaced  prior  to  the  heater  being  put  into  operation.  The 
replacement hose assembly shall be that specified by the manufacturer. 

 
3.  The flow of combustion and ventilation air must not be obstructed. Be sure to 

check  the  fan  assembly  and  ensure  that  the  motor  and  blade  are  operating 
properly. 

 
4.  Compressed  air  should  be  used  to  keep  components  free  of  dust  and  dirt 

build up. Note:  Do not use the compressed air inside any piping or regulator 
components. 

 
5.  Change  fuel  filter  insert  (Part#  FVO-418)  once  per  month.  Change  fuel  filter 

cartridge (Part# FVO-419) once every 6 months. 

 
6.  Change oil nozzle (Part# FV-235B) once per year. 
 
7.  Fan  Limit  Switch  (Part#  FV-407A)  should  be  replaced  if  the  fan  motor  does 

not shut off after the heat exchanger has cooled down. 

 
8.  The High Limit Switch (Part# FV-406) should be checked each season. This 

limit switch will ensure the burner shuts down if the temperature exceeds 250º 
F at the outlet. 

 
9.  Fuel tank should be drained on a regular basis by removing drain plug. 

 

10. 

 CAUTION

  –  Do  not  have  any  source  of  ignition  near  the  heater  when 

draining tank. 

NOTE:

 

No.1 fuel oil or kerosene is recommended for temperatures below  

Summary of Contents for FVO-200RC

Page 1: ...T FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U S A As per CSA B140 8 Portable Oil Fired Heaters CSA B140 02003 Oil Burning Equipment UL733 Oil fired heaters Construction Heaters Unattended Ty...

Page 2: ...ON SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DIS...

Page 3: ...HORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these SPECIF...

Page 4: ...This heater will operate with No 1 No 2 Diesel or Kerosene Note No 1 Fuel Oil or Kerosene must be used for temperatures less than 10 C 8 F ELECTRICAL WARNING Electrical Grounding Instructions This app...

Page 5: ...PPLY BEFORE TURNING HEATER ON FAILURE TO DO SO WILL VOID ANY WARRANTY FLUE PIPE Flue pipe connection must terminate with a vertical run at least 2ft long Horizontal runs should have a rise ratio of 1...

Page 6: ...MINIMUM OF 2FT HIGHER THAN ANY POINT WITHIN 10FT B MAXIMUM HORIZONTAL RUN IS 30FT NOTE 90deg ELBOW 10ft HORIZONTAL VENT ALLOWANCE 45deg ELBOW 5ft HORIZONTAL VENT ALLOWANCE C VENT TERMINATION IN HORIZO...

Page 7: ...hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall be that specified by the manufacturer 3 The flow of combustion and ventilation air must...

Page 8: ...oblem Correct power supply problem before operating heater 6 Move toggle switch to MANUAL position for manual control 7 Move toggle switch to THERMOSTAT position for thermostat control Thermostat must...

Page 9: ...heater to start properly 3 Make sure there are no air locks in fuel lines or filter 4 Ensure proper power supply and extension cord is being used 5 Check for dirty fuel filter or blocked fuel supply...

Page 10: ...y guards or performing any maintenance be sure that the main power supply is disconnected COMBUSTION AIR ADJUSTMENTS NOTE Proper combustion air adjustment must be achieved using a certified combustion...

Page 11: ...O2 and temperature readings may be experienced when the burner cover is put in place Therefore the burner cover must be in place when making the final combustion instrument readings to ensure proper t...

Page 12: ...r application Turn the temperature feeler gauge so that the holes are parallel with the heat exchanger This will help the fan switch to remain cool and not overheat See following If supply air is cold...

Page 13: ...13 WARNING DO NOT activate burner until proper oil line connections have been made or failure of the pump shaft seal may occur...

Page 14: ...14 WARNING If a neutral or ground lead is attached to this terminal the CONTROL BOX on the burner will be damaged should lockout occur...

Page 15: ...fully pulling it back and then up B Remove the AIR TUBE COVER PLATE 5 by loosening the two retaining SCREWS 4 C Loosen SCREW 2 and then slide the complete drawer assembly out of the combustion head as...

Page 16: ...2 from the DRAWER ASSEMBLY by loosening the SCREW 1 B Insert the proper NOZZLE into the NOZZLE ADAPTER and tighten securely Do not over tighten C Replace adapter with nozzle installed into drawer ass...

Page 17: ...ressure gauge is attached to the PRESSURE PORT 8 for pressure readings Two PIPE CONNECTORS 5 are supplied with the burner for connection to either a single or a two pipe system Also supplied are two A...

Page 18: ...OSTAT FAN MOTOR FV 200 WIRING SCHEMATIC FV 200 WS 2011 FV 200 SERIES WIRING SCHEMATIC 2011 FLAGRO INDUSTRIES LIMITED SWITCH BURNER REAR HIGH LIMIT SWITCH FRONT HIGH LIMIT SWITCH L1 N G G X RED LIGHT P...

Page 19: ...2P05RC Motor Mount Bracket FV 208RC Recirculating Hood FV 208IFP Canopy Inner Faceplate FV 208IR Canopy inlet Ring FV 2P08RC Control Box FV 2P09RC Control Box Lid FV 406 High Limit Switch Outet 250F...

Page 20: ...FV 461 Inlet Outlet Burner Pump Fitting FVO 223 7 Copper Pick Up Tube c w Adapter FV 231 Burner Gasket FV 433 Feeler Gauge FV 234CB12 Front Face Plate 1 x 12 FV 234CB16 Front Face Plate 1 x 16 FV 235...

Page 21: ...1 2 4 18 19 20 21 22 A B B B 23 24 25 26 28 30 31 32 33 34 35 36 38 39 37 40 40 27 27 F 5 OIL FIRED BURNER PARTS DIAGRAM...

Page 22: ...034 BURNER MOTOR 25 FVO 3007316 AIR TUBE COVER PLATE 26 FVO 3002280 PHOTO CELL 27 FVO 3005854 SEMI FLANGE 28 FVO 3005855 MOUNTING FLANGE 30 FV 3005708 BURNER FAN 31 FVO 3005844 BURNER CAPACITOR 32 FVO...

Reviews: