ELECTRODE SETTING
OIL LINE CONNECTIONS
Note:
Pump pressure must be set at time of burner start-up. A pressure gauge
is attached to the PRESSURE PORT (8) for pressure readings. Two PIPE
CONNECTORS (5) are supplied with the burner for connection to either a single
or a two-pipe system. Also supplied are two ADAPTORS (3), two female 1/4”
NPT, to adapt oil lines to burner pipe connectors. All pump port threads are
British Parallel Thread design. Direct connection of NPT threads to the pump will
damage the pump body. Riello manometers and vacuum gauges do not require
any adaptors, and can be safely connected to the pump ports. An NPT (metric)
adapter must be used when connecting other gauge models.