background image

Certified for shock and electrical fire hazard only. 

 

INTRODUCTION 

 
 

DESCRIPTION

 

 
The SC Series Electronic Air Cleaners are self-contained 
units  comprised  of  collecting  cell(s),  electrical 
compartment,  blower  and  motor  assembly,  complete 
cabinet  housing,  prefilter(s)  and  after  filter(s)  or  optional 
carbon filter(s). 
 
There are two sizes available:  
 
Model SC-910: up to 1100 CFM capacity at 90% 
efficiency 
Model SC-924: up to 2100 CFM capacity at 90% 
efficiency 
 
The efficiency of the above units are rated on the removal 
of particulate matter down to .01 micron including welding 
fumes,  automotive  grinding  dust,  oil  mist  and  carbon 
black  dust.  On  larger  particulate  matter  such  as  .03 
micron,  it  is  possible  for  efficiencies  to  reach  as  high  as 
99%.  This is based on the ASHRAE standard Dust Spot 
Test. 
 
 

HOW IT WORKS

 

 
The  Electronic  Air  Cleaner  operates  on  the  principle  of 
"Electrostatic Precipitation". Millions of airborne pollutants 
are drawn in through the intake grill on the front of the air 
cleaner  and  first  pass  through  a  prefilter  where  large 
particles are caught. Next, smaller particles move to a two
-stage electrostatic collecting cell where they are given a 
powerful  positive  charge  by  the  ionizing  wires.  Charged 
particles  then  move  into  the  collecting  area  where  they 
are  attracted  to  a  series  of  alternately  charged  and 
grounded  plates.  Pollutants  are  held  on  the  plates  like  a 
magnet  until  washed  away  during  cleaning.  Clean  air  is 
then dispersed through the exhaust grill. 
 

MAJOR COMPONENTS 

 

CABINET

 

 
The cabinet is constructed of 18 gauge steel finished in a 
scratch-resistant,  electrostatic  powder  coated  finish.  The 
unit  has an interlocked cell access door, and two blower 
access  doors.  The  removeable  intake  grill  is  20  gauge 
expanded  metal  screen.  Air  is  discharged  through  a  4-
way  directional  defuser.  Weld  nuts  to  accept  1/2  in. 
threaded  rods  are  incorporated  into  the  cabinet  top  to 
facilitate hanging the unit. 
 

PREFILTERS

 

 
The washable prefilter measuring 16 x 20 in (40.6 x 50.8 
cm)  is  constructed  of  multi-layers  of  aluminum  mesh  for 
maximum filtration of large particles. 

 
AFTER FILTER 
 

The  after  filter  measuring  16  x  20  in  (40.6  x  50.8  cm)  is 
constructed of multi-layers of aluminum mesh for filtration 
of agglomerated dust, and to maintain back pressure. 

 
COLLECTING CELL

 

 
The  two  part  collecting  cell  include  support  brackets, 
collecting  plates,  support  tubing,  insulators,  end  plates, 
spring  contact,  access  handles,  and  separate  ionizing 
section; ionizing wires, ionizing wire support.  

 
MOTOR & BLOWER 

 
The motor  is  3/4  HP  TEFC,  1725  RPM.  The  blower  is  a 
double  inlet,  centrifugal  type  with  a  forward  inclined 
wheel. 
 

ELECTRICAL COMPARTMENT

 

 
The control panel on the front of the unit contains the two 
lighted  rocker  switches  to  control  the  motor  and  power 
board,  and  a  performance  indicator  light,  indicating  high 
voltage. 
 
The  high  voltage  power  board  is  located  in  a  separate 
removable  steel  box  mounted  below  the  blower  motor. 
The power board is an open printed circuit board with an 
adjustable  output.  The  direct  current  output  is  10,000 
volts  @  3.5  mA.  It  is  fused  at  1.5  amps.  A  large  value 
resistor bank will bleed off the high  voltage from the  cell 
when the unit has been turned off. 
 
Quick  disconnects  on  the  board  allow  easy  removal  for 
troubleshooting  or  repairs. 

The  Performance  Indicator 

Light should be on during normal operation.

 The light 

will  flicker  with  arcing  in  the  cell  or  extinguish  if  the  cell, 
ionizer or power board is shorted. 
 
The  cell  access  door  is  equipped  with  a  safety  interlock 
switch  to  cut  the  power  to  the  unit  when  the  door  is 
opened. 

Electrostatic Precipitation 

 

2 Prefilter 

1 Dirty Air 

3 Ionizing Section 

4 Collecting Cell Plates 

6 Clean Air 

5 After Filter or 
Carbon Filter 
(optional) 

Summary of Contents for SC-924-1

Page 1: ...OPERATION MAINTENANCE MANUAL MODEL SC 924 1 SELF CONTAINED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Page 2: ... is discharged through a 4 way directional defuser Weld nuts to accept 1 2 in threaded rods are incorporated into the cabinet top to facilitate hanging the unit PREFILTERS The washable prefilter measuring 16 x 20 in 40 6 x 50 8 cm is constructed of multi layers of aluminum mesh for maximum filtration of large particles AFTER FILTER The after filter measuring 16 x 20 in 40 6 x 50 8 cm is constructe...

Page 3: ...lication If your unit is equipped with an activated carbon filter it will need to be refilled depending on the environment every 3 6 months Do not wash the carbon filter as this will render it useless WASHING INSTRUCTIONS 1 Turn both the fan and power supply switches OFF and wait 15 seconds for high voltage to dissipate 2 Open the cell access door and remove the collecting cells ionizers prefilter...

Page 4: ... compressed air or vacuumed particularly around the cooling fan intake at the back of the motor CLEANING AND SERVICE The use of DAX Detergent is recommended for cleaning as it is a heavy duty solution used expressly for removal of accumulated pollutants on cell plates If used as directed DAX will not harm aluminum or steel if used as directed Any problem arising out of the use of another cleaning ...

Page 5: ......

Page 6: ......

Page 7: ...ses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the control of FIVE SEASONS COMFORT LIMITED 6 Parts not supplied or designated by FIVE SEASONS COMFORT LIMITED 7 FIVE SEASONS COMFORT LIMITED products installed outside the continental C...

Reviews: