CLEANING INSTRUCTIONS

 

The prefilter and collecting cell must be washed on a regular 
basis  for  the  Air  Cleaner  to  function  at  its  peak  efficiency.  
The frequency of cleaning will vary from one environment to 
another,  therefore  the  cell  should  be  checked  monthly  to 
determine cleaning schedule.  On average, the cell should be 
washed every 2-3 months. 

COLLECTING CELL

 

1.  Turn  Air  Cleaner 

OFF

.    Remove  the  cell  from  the  Air 

Cleaner.    Slide  the  prefilter  and  carbon  filter  out  of  the 
retaining brackets before cleaning. 

2.  Rinse  prefilter and  cell,  and  spray  completely  with  DAX 

Detergent (or non-chlorine, non-corrosive, non-abrasive, 
non-ammonia liquid household detergent).  Let stand for 
5  minutes.    Rinse  well  with  hot  water  (120°F  /  49°C 
maximum). Repeat process 3 times. 

3.  If  dirt  remains,  let  cell  soak  in  a  solution  of  DAX 

Detergent and hot water for 30 minutes. 

4.  For  drying,  place  the  cell  on  a  45°  angle  on  one  end, 

with the arrow pointing sideways, and let stand for 10-24 
hours.    A  hair  dryer  may  be  used  to  speed  up  drying 
time.    Make  sure  the  cell  is  completely  dry  before 
reinserting  back  into  Air  Cleaner.  The  arrow  on  the cell 
must point toward the fan blower. 

5.  If arcing or snapping occurs or the lights do not come on 

when  the  cell  is  placed  back  in  the  unit  and  turned  on, 
then remove the cell and allow to dry longer. 

ODOR & GAS (VOC) REMOVAL FILTER 

 
 

 
 
1.  The Activated Carbon Odor & Gas (VOC) Removal Filter 

must  be  replaced  at  regular  intervals  if  odor  removal  is 
desired  (approximately  every  3-6  months). 

ODOR REMOVAL FILTERS ARE NOT WASHABLE.

 

CABINET 

1.  Turn Air Cleaner 

OFF

2.  A soft, damp, lint-free cloth may be used to remove dirt 

and  fingerprints  from  painted  surfaces,  grills  and  end 
panels. 

NEVER  USE  AN  ABRASIVE  CLEANER  ON  THE 
CABINET.

 

WARNING 

DO 

NOT 

WASH 

COLLECTING 

CELL 

IN 

DISHWASHER

.

 

Never use any object to clean between the cell plates as 
this may cause damage to the plates or ionizing wires. 
Never place the cell in an oven to dry. 
The edges of the cell may be sharp — handle with care. 

 
 
 
 
 

TROUBLESHOOTING CHART 

 
The  two  Operation  Lights,  located  behind  the  front  grill,  are 
also  used  as  the  high  voltage  fault  indicator.    If  the  fan  is 
operating,  but  the  lights  do  not  come  on,  then  there  is  a 
problem  in  the  high  voltage  circuit.    To  determine  what  the 
problem  is,  turn  the  Air  Cleaner 

OFF

  and  remove  the 

collecting  cell.    Close  the  lid  and  turn  the  Air  Cleaner  back 

ON

.  If the lights come back on, the problem lies in the cell.  

Check the cell for wetness from washing or look for a broken 
ionizing wire(s) or bent cell plate(s). 
 
If  the  lights  do  not  come  on,  the  problem  is  with  the  power 
board or Operation Light(s).  If you are unable to correct any 
of the above problems, call 1-800-267-8305.

 

TECHNICAL DATA

 

PROBLEM 

CAUSE 

Fan does not operate 
Both Operation Lights off 

Unit not plugged in 
System switch not 

ON

 

Fan switch not in proper position 
Lid not securely closed 

Green Performance 
Light on 
Red Ion Light off 

Negative  Ion  switch  not  in 

ON 

position 

Fan operating 
Both Operation Lights off 

Cell wet from washing 
Short in cell (see below) 

Cell arcing excessively 

Cell wet from washing 
Cell plate(s) bent 
Cell  dirty  or  large  lint  ball/hair 
caught in cell 
Broken ionizing wire(s) 
Prefilter  is  in  backward  (black  
mesh should be visible on outside) 

Air Cleaner vibrating 
excessively 

Unit not sitting on flat surface 

Both Operation Lights on 
Cell not collecting dirt 

Cell is  in  backward  (Arrow  on  cell 
should point towards fan blower) 

Dimensions 

Width 

Depth 

Height 

 

20.0 in 
12.0 in 
  5.0 in 

 

50.8 cm 
30.5 cm 
12.7 cm 

Weight 

  16.0 lbs 

  7.3 kg 

Input Voltage 

120 V        60 Hz 
220 V        50 Hz 

220 V        60 Hz 
220-240 V 50 Hz 

Power Consumption 
(maximum) 

85 Watts 

 

Air Flow 

High 

Medium 

Low 

 

130 cfm 
  80 cfm 
  60 cfm 

 

221 m³/hr 
136 m³/hr 
102 m³/hr 

Cell Output Voltage  

6500 VDC @ < 1 mA 

 

Collecting Cell 
Surface 

756 in² 

4877 cm² 

Negative Ionizer 

-5000 VDC @ <.1 mA 

 

Negative Ion Output 

2 x 327.7 K/in³ 

2 x 20 K/cm³ 

Ideal for rooms up to:  
(1 room air change 
every 20 minutes for 
maximum room size) 

 

320 ft² 

 

29.5 m² 

Activated Carbon 
Odor & Gas (VOC) 
Filter 
 
Prefilter 

Collecting Cell 

DAX Detergent, No. 9900, and 
the Activated Carbon Odor & 
Gas (VOC) Removal Filter, 
No. 59-0810, are available 
from your retail outlet.

 

Summary of Contents for 590AIV

Page 1: ... tobacco smoke cooking smoke and grease and more down to 0 01 micron Activated Carbon Odor Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at a glance Ide...

Page 2: ...ich activates Safety Interlock 2 Negative Ion Emitter 3 Negative Ion Control Switch 4 3 Speed Fan Control Switch 5 System Switch 6 Operation Lights 6 The Fan Control Switch in the front position is low speed the center position is medium and the rear position is high speed 7 The negative ions are controlled by a separate switch located behind the fan control switch When the switch is ON the red li...

Page 3: ...handle with care TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine what the problem is turn the Air Cleaner OFF and remove the collecting cell Close the lid and turn the Air Cleaner back ON If the lights...

Page 4: ...oft surfaces i e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source i...

Reviews: