background image

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

THIS MANUAL SHOULD BE READ AND UNDERSTOOD BEFORE OPERATING THIS 

FORCE PLATE 

 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Do not hesitate to contact us if you have any questions about this product 

 

 
 

 
 
 
 
 
 
 
 
 

Fitness Technology

 

21 Bishop St. 

Skye SA 5072 

Australia 

Postal Address: PO Box 139 Fullarton 5063 

+61 418815400 

Mob: 0418 815 400 

www.fittech.com.au [email protected]  

 
 

Copyright:   Fitness Technology, Adelaide, Australia 03 February 2020 

 

FORCE PLATE 

 

400S+ Performance Force 

Plate Manual 

Summary of Contents for 400S+

Page 1: ...ave any questions about this product Fitness Technology 21 Bishop St Skye SA 5072 Australia Postal Address PO Box 139 Fullarton 5063 61 418815400 Mob 0418 815 400 www fittech com au E info fittech com au Copyright Fitness Technology Adelaide Australia 03 February 2020 FORCE PLATE 400S Performance Force Plate Manual ...

Page 2: ...lia 3rd Feb 2020 Issue 1 00 3rd Feb 2020 Contents Specifications 2 Load Cell Wiring 3 Installation 4 USB and PT5A position Transducer Cable Connections 4 Installation of 4 x Platform Feet 6 Levelling the 400S Performance Force Plate 6 Care and Maintenance of Force Plate 7 PRECAUTIONS 7 Warranty 7 Frequently Asked Questions 8 Q How do you calculate your variables 8 Q What is the sampling period for...

Page 3: ...0S force plate Only Performance Force Plate on the market capable of running on our new InnerBalance software tracking used to measure record all anterior posterior mediolateral sway movements Weight 400S 14 5 Kg 32 lbs Operation Integral PCB Module operates 4 Load Cells Output powered via 5 V DC Computer USB Port only Sensor type Steel Shear Beams rating 250Kg 3mV V that are genuinely rated to sa...

Page 4: ...oad Cell Wiring The four Load Cells connect into the XPV7 Electronics Module are colour coded on the load cell cables at the terminal blocks for ease of wiring they are as follows Load Cell 1 Blue Heat Shrink shroud as per next page Load Cell 2 Green Heat Shrink shroud as per next page Load Cell 3 Red Heat Shrink shroud as per next page Load Cell 4 Yellow Heat Shrink shroud as per next page The wi...

Page 5: ...form by rotating the feet to the right right hand thread Adjust height as show below 4 Connect the USB communication cable as shown below by removing the plug allowing access to the communications port See photos below 5 The Platform is now ready for use 6 Install the communications software and the processing software following the instruction for each module 7 The XPV7 PCB Electronics Module wil...

Page 6: ...m au Copyright Fitness Technology Adelaide Australia 3rd Feb 2020 Issue 1 00 3rd Feb 2020 In the image above you can see the USB connector for the Force plate and the cat5e connector for the LPT Both are tucked back in under the rear cover for shipping See below for an example of the PT5A position transducer connected to the 400S Performance force plate USB Connector Cat5e Lead connects to RJ45 So...

Page 7: ...tch threads are installed in each of the four corners They screw into the Platform with standard a right hand thread Stainless Steel M12 spacer Nuts are used for levelling and adjusting the height of the Platform If required the M12 spacer nuts can be removed but if this is done never thread the 4 x feet threads thru all the way back off 5mm See page 11 for more detail Levelling the 400S Performan...

Page 8: ...ny part that is proved to be defective due to faulty workmanship Defects or failures in equipment which under proper use appear therein and arise solely from faulty materials or workmanship will be remedied by us free of charge provided the equipment is returned to our Workshop within a period of twelve 12 months from date of delivery freight paid both ways In the case of warranty service to equip...

Page 9: ...erive the velocity time data set 3 Velocity data is then integrated over time to derive the displacement time data set 4 Power is calculated as instantaneous velocity multiplied by instantaneous force that each time point 5 Maximum and minimum as well as average summary variables are being calculated for each data set 6 Additional summary variables such as impulse over defined time periods time to...

Page 10: ...SA 5072 Australia Postal Address PO Box 139 Fullarton 5063 Tel 61 8 8331 9229 Mob 0418 815 400 www fittech com au E info fittech com au Copyright Fitness Technology Adelaide Australia 3rd Feb 2020 Issue 1 00 3rd Feb 2020 For any additional support information send email request to info fittech com au ...

Reviews: