EasyGrid Base User Guide v1.0
12
4.5 Powering the EasyGrid Base
The EasyGrid Base requires a 24V DC power
supply.
The power input terminal block is located at the bottom left of the terminal face panel.
There is no Power Switch per say. As soon as connected, it is energized and powered up.
1.
Connect the unit to the power supply using terminal block connectors V+, V-
2.
Wire the power input terminal block to a power supply providing the required
voltage and power.
Please refer to the power supply operating guide for important notices and installation
information.
WARNING
To avoid damage to the unit, make sure that the power fed into the input complies with
technical specifications. No other voltage level or range is accepted.
4.6 Optical Connectors
There can be up to 12 optical channels on each EasyGrid Base. Each
channel is designed to be connected with a fibre Optic extension, an
EasyThrough and a Fiber Optic sensor.
CAUTION
Use care in handling fiber optic connectors. Always clean the fiber tip prior to insertion into
the connector for optimum performance. For details on connector handling and
maintenance, please refer to Cleaning Procedure section.
To connect a ST connector, follow these 5 steps:
1.
Remove the protective cap from the Male ST Connector and ST Mating
2.
Use the One-Click-Cleaner tool to clean the Male ST connector and the ST Mating
3.
Align the male connector key with the mating slot
4.
Insert the connector in the mating
5.
Twist to lock