FISNAR RVC900N Series User Manual Download Page 4

RVC900N

 Rotary Valve Controller 

 

Rev. A - Nov. 10 

 

 

 

2. DESIGNATED USE 

 
The  digital  rotary  valve  controller  RVC900N  is  used  for  precise  controlling  of  rotary 
valves which work with a DC voltage of 0 

 24V, for example the PDV-1000 valve. The 

RVC900N  controls  the  air  pressure  on  the material,  and  also  the  voltage  to  the  rotary 
valve for setting the speed of the valve.  
With the integrated precision air pressure regulator, the air pressure on the material can 
be  set  precisely.  There  are  two  different  air  pressure  outputs  for  the  RVC900N.  One 
output is continuous air pressure, the second output is a pulsed air pressure, as long, as 
the rotary valve dispenses. An integrated digital pressure sensor at the inlet air gives an 
additional point for the process safety. 
 
 

3. FOR YOUR SAFETY:  

 

WARNING:

  

  If the RVC900N is used for other functions as described below, it could come to 

personal or material damage. Use the RVC900N controller only for the functions, which 
are explained in this user manual. Fisnar Inc. is not responsible for personal or material 
damages, which happen because of incorrect usage.  
 

 

DO NOT

 modify the RVC900N.  

 

DO NOT

 attempt to repair or use spare parts without first contacting Fisnar.  

 

DO NOT

 use anything but recommended Fisnar accessories.. 

 

SAFETY PRECAUTIONS: 

  The RVC900N works with 100 

 240V AC voltage. By touching the 100 

 240V AC 

voltage, there exists danger of life!! Because of this, the RVC900N must be 
disconnected from the AC input cable, before opening the housing. It is only allowed for 
authorized electrical experts to open the housing. 

  DO NOT exceed the maximum allowed power / settings. 
  Always wear protective gear. 
  Before using the RVC900N please review the safety datasheets of the dispensing 

material 

  No smoking or fire by flammable materials. 
  The RVC900N is only allowed for use indoors. 
  Due to the electronic nature of this equipment and the potential for a spark or 

generation of heat, note that this equipment most 

NOT

 be used with any explosive 

material or in an explosive type environment. 

 
 
 
 
 
 

Summary of Contents for RVC900N Series

Page 1: ...RVC900N Rotary Valve Controller Rev A Nov 10 RVC900N Series ROTARY VALVE CONTROLLER U Us se er r M Ma an nu ua al l...

Page 2: ...RVC900N Rotary Valve Controller Rev A Nov 10 This page intentionally left blank...

Page 3: ...1 Parts description 4 5 Included parts 5 6 Start operation 5 7 Operation 6 7 1 Display 6 7 2 Status LED s 6 7 3 Operation keys 7 8 Parameter 8 9 Service Menu 9 9 1 Display 9 9 2 Settings 9 10 Electri...

Page 4: ...00N controller only for the functions which are explained in this user manual Fisnar Inc is not responsible for personal or material damages which happen because of incorrect usage DO NOT modify the R...

Page 5: ...lbs 1 65kg Power Supply 100 240V AC 50 60Hz Internal Voltage 24V DC Voltage Rotary Valve 0 24V DC PWM Dispense Time 0 01 999 sec Air Inlet 0 100psi 0 7bar Display digital Air Outlet 0 58 psi 0 4bar pr...

Page 6: ...Front Side Back Side Pressure gauge for air outlets Air pressure regulator Operating keys Status LED s Graphic display Rotary valve 0 24V DC PWM Footswitch Power switch Air outlet continuous Air outl...

Page 7: ...nding on your application use the continuous or pulsed air outlet for the air supply of the material reservoir Adjust the air outlet pressure with the pressure regulator on the front side of the RVC90...

Page 8: ...ndependent to the rotation direction ALARM The ALARM LED lights during the following conditions Pressure alarm is active Motor current overload only active for speed 50 External alarm signal on the I...

Page 9: ...2 sec and select the wanted program with the UP DOWN keys and press SAVE again to store the parameters If no different program is selected the parameters get automatically saved in the actual program...

Page 10: ...e can be selected in linear steps The value from 001 100 is related to the rotary valve voltage 0 24V Set the wait time The wait time is the pause time between end of dispensing and starting the retra...

Page 11: ...CW Counter clockwise spindle moves counter clockwise P Unit Pressing UP DOWN keys switches between PSI and BAR as unit for the digital displayed pressure P Alarm By pressing the UP DOWN keys the value...

Page 12: ...nsing 10 3 I O Port type 15 pol SubD female 2 doublerow pins see following chart pin no Input Output Description Comment 1 Reserved Reserved 2 GND GND 3 24V DC 24V DC 4 Output BUSY Dispensing procedur...

Page 13: ...0 11 10 4 Wiring Diagrams Digital Inputs A digital input is active if the opto coupler is ON If the opto coupler is connected to GND the input is activated Digital Outputs If the digital output is act...

Page 14: ...be done by the manufacturer Clean the RVC900N controller only with a clean smooth and dry cloth Do not use dissolvent material to clean the RVC900N controller The foil at the front back plate or the...

Reviews: