Keylock:
By pressing SAVE + PRG at the same time, a key lock for the RVC900N can be activated.
An activated key lock is shown in the display (lower right hand corner) with the symbol:
By pressing SAVE + PRG again, the keylock is deactivated.
9. SERVICE MENU: (press the UP + DOWN keys during initialisation)
9.1 Display:
9.2 Settings:
Language:
Pressing UP / DOWN keys switches between English and German language.
Direction:
Pressing UP / DOWN keys switches between CW / CCW rotating direction for the rotary
valve:
CW:
Clockwise - spindle moves clockwise
CCW:
Counter clockwise - spindle moves counter clockwise
P-Unit:
Pressing UP / DOWN keys switches between PSI and BAR as unit for the digital displayed
pressure.
P-Alarm:
By pressing the UP / DOWN keys, the value for the low pressure alarm-limit can be
selected. If the input pressure is lower than the selected limit, the RVC900N controller
switches to ALARM mode and no new dispensing is possible.
Service:
Service counter
–
not resettable
NOTE:
Press the save key to store new settings. The unit will reboot itself.
If you do not want to store new settings, turn off the power and turn on again.