background image

 
 

3 of 16 

 

 
The purpose of this manual is to provide users and operators with the necessary information to use the couch 
properly, autonomously, and safely. 
This manual contains information on the technical features, operation, maintenance, spare parts and security 
of the couch. 
This  manual  must  always  be  carried  with  the  equipment  and  stored  with  care  so  that  the  readability  is  not 
compromised. 
In  case  of  transfer  of  use  to  a  third  party,  this  manual  must  be  transferred  as  well,  along  with  the  other 
documents, as provided by Council Directive 93/42/EEC.  
 

Intended use 

The  ANDROMEDA  /  ANDROMEDA  LARGE  couch  is  a  professional  couch  used  by  rehabilitation  and 
physiotherapy professionals.  
 

Manufacturer’s details 

FISIOTECH SRL  
Operating headquarters: Via Toniolo, 44/E-F  
31028 VAZZOLA (TV) - Italy 
Tel. +39 0438 470342 
Fax +39 0438 478762 

[email protected]

  

 

Area of use 

The medical devices described in this manual comply with the Directive 93/42/EEC as modified by Annex VII 
to Directive 2007/47/EC. Area of use: outpatient care carried out under medical supervision in hospital or in 
another  medical  centre  where  the  medical  electrical  equipment  are  used  for  the  treatment,  diagnosis  and 
monitoring of sick patients, people who have sustained injuries and people with disabilities. 
 

Storing 

In case of storing, the following  environmental conditions must be ensured: relative humidity  10% ÷ 90 %  - 
temperature -10°C ÷ +50°C 

– Clean place. 

 

 

WARNING!  Thoroughly read the manual before use.  

 

FISIOTECH SRL refuses any responsibility and is not liable in case any 
damage to people and/or goods caused by the improper use of the couch, 
by  negligent  or  not-qualified  staff  or  by  non  compliance  with  these 
instructions occurs. 

 

 
 
 
 
 
 
 

Summary of Contents for 112131

Page 1: ...Rev 05 09 2020 USE AND MAINTENANCE MANUAL ANDROMEDA ANDROMEDA LARGE COUCH SIMPLE SERIES ANDROMEDA COUCH MODELS Description Code Andromeda with foot pedal 112131 Andromeda LARGE with foot pedal 112141...

Page 2: ...ING p 5 PRODUCT LABEL AND SYMBOLS p 6 TECHNICAL SPECIFICATIONS p 7 TECHNICAL SPECIFICATIONS OF THE POWER GRID p 8 WARNINGS p 9 HOW TO USE THE COUCH p 10 11 PROBLEMS CAUSES AND SOLUTIONS p 12 MAINTENAN...

Page 3: ...ia Toniolo 44 E F 31028 VAZZOLA TV Italy Tel 39 0438 470342 Fax 39 0438 478762 info fisiotech com Area of use The medical devices described in this manual comply with the Directive 93 42 EEC as modifi...

Page 4: ...Always unplug the device before working on any electrical part or before moving the device Do not damage the cables avoid crushing the cables do not unplug by pulling the cable pull the plug instead e...

Page 5: ...erational headquarters and prior authorization The products to be repaired under warranty must be shipped to the manufacturer freight prepaid and with the original packaging A copy of the invoice and...

Page 6: ...g Temperature limit Humidity limitation Keep away from sunlight and heat sources Keep away from rain Read the instructions This symbol on a product means that it should not be thrown with regular wast...

Page 7: ...80 Maximum static working load 200 kg evenly distributed Under bed clearance 17 cm Lateral offset 32 cm Power supply 230V 50Hz Powder coated steel frame 4 cm thick polyurethane foam fireproof padding...

Page 8: ...d Low voltage 24V direct current motor Low voltage 24V foot switch hand control Automatic limit switch With resettable thermal fuse WARNING Please note that the actuator motor should be ran intermitte...

Page 9: ...w in order so avoid pinching crushing 2 Not to sit on the headrest 3 Not to sit or concentrate load on the extremities of the couch head backrest footrest WARNING The professional should never leave t...

Page 10: ...is carried out through the foot pedal L1 lever The headrest can be adjusted through a gas spring operated with a specific lever In order to adjust the inclination pull the lever L1 and set the desired...

Page 11: ...6 PAPER ROLL HOLDER Raising the cot sides Lift both cot sides simultaneously and fasten them Lowering the cot sides Lower both sides simultaneously COTSIDES The paper roll holder is placed under the f...

Page 12: ...The actuator motor does not work Major problem e g blown fuse or broken control box Please refer to the vendor The actuator makes screeching noises There is dust on the stem Dust the stem with a non a...

Page 13: ...oid and the manufacturer will not be liable for any damage MAINTENANCE WHAT TO DO Electrical parts No maintenance needs to be carried out on the actuator apart from what was mentioned under Troublesho...

Page 14: ...y that this operation is carried out correctly Light colours should not come into contact with fabrics and clothes which have been treated with unbound dye or not properly dyed in order to avoid colou...

Page 15: ...121301 Complete padding for ANDROMEDA couch MIM1121401 Complete padding for ANDROMEDA LARGE couch CODE DESCRIPTION 120010 Paper roll holder for electrical couches 120060 60cm wide 65mt long double ply...

Page 16: ...16 of 16 INSPECTION RECORD SHEET DEVICE MODEL CODE INSTALLATION DATE SERIAL No Inspection Date Maintenance Name of the inspector Signature...

Reviews: