9.2 Indoor Unit Error Display
Display
STATUS
E1 EEPROM
error
E2 Zero-crossing
examination
error
E3
Fan speed beyond control
E4
Over current protection of the compressor occurs 4 times
E5
Open or short circuit of Room temperature sensor
E6
evaporator temperature sensor open or short circuit of
9.3 Diagnostic chart
After energizing, no indicator is lighted and the air conditioner can’t be operated.
After energizing, the air conditioner can not be operated.
Check if AC 220V power supply outputs to indoor PCB.
Check if AC 220V exists at the primary coil of transformer.
Yes
YES
No
Check if AC 14.5V exists at the secondary coil of transformer.
Indoor PCB is defective.
Take off the secondary plug of transformer, and then check if AC
14.5V exists at the secondary coil of transformer.
No
Yes
Yes
Indoor PCB is defective.
Indoor PCB is defective.
No