Fisher & Paykel PHASE 7 INTUITIVE ECO IWL16-US Service Manual Download Page 6

517793A 

 

 

1.7 Water 

Valves 

Supply

 

Mode of Operation

 

Voltage

 

Resistance

 

Flow Rate

 

Cold 

Digitally Operated 

24V DC 

64

 @ 68

 o

F / 20

o

16 liters per minute 

Hot Digitally 

Operated

 

24VDC 64

 @ 68

 o

F / 20

o

10 liters per minute 

 
Note: Flow rate will vary slightly depending on pressure. 

 
Operating pressures: 

Maximum 150psi / 1034 kPa - Minimum 5psi / 34 kPa  

  

Note:  Pressures below 5psi / 34kPa can create seating problems with the internal 
diaphragm of the valve, and may cause water to drip into the inner basket when the 
machine is not in use. 

 

1.8 Thermistor 

NTC-type temperature sensor (Thermistor) 

Resistance 10,000

 @ 77

 o

F / 25

o

 

1.9 Cabinet 

Pre-painted steel 

1.10 Lid 

 

ABS plastic (co-injected) 

1.11 Top 

Deck 

Polypropylene 

1.12 

Inner Basket  

Stainless steel: Grade 430T 
Basket base and balance ring: Polypropylene 
 
The inner bowl on the large machine has a 
series of small bumps around the base of the 
inner bowl.  These bumps are designed to 
improve wash performance by increasing load 
turnover and movement. 
 

Note: The inner bowl is backwardly 
compatible with all earlier large machines.   

 
 

 

 

Inner Basket Weight 

Large 

23.10lb +/- 9.7oz / 10.480kg +/- 275g 

 

Inner basket speed 

Fast Spin 

1,000 RPM 

Medium Spin 

670 RPM 

Slow Spin 

300 RPM 

Stir Speed 

25 RPM 

 

Summary of Contents for PHASE 7 INTUITIVE ECO IWL16-US

Page 1: ...517793A INTUITIVE ECO PHASE 7 Electronic Washing Machines IWL16 US Supplementary Manual to 517792A ...

Page 2: ...FEBRUARY 2005 REPRINT The specifications and servicing procedures outlined in this manual are subject to change without notice The latest version is indicated by the reprint date and replaces any earlier editions ...

Page 3: ...PHASE 7 INTUITIVE ECO ELECTRONIC WASHING MACHINE Covering the following product codes IWL16 US 96203 Fisher Paykel Appliances Inc 5800 Skylab Road Huntington Beach California CA92647 USA Ph 888 936 7872 F P Ph 888 396 2665 DCS ...

Page 4: ...6 1 13 Outer Basket 7 1 14 Console 7 1 15 Agitator 7 1 16 Fabric Softener Dispenser 7 1 17 Electric Supply 7 1 18 User Information 7 1 19 Lid Lock 7 1 20 Control Panel Intuitive Eco 7 2 LID LOCK 8 3 SIZE SETTING 8 4 DIAGNOSTIC MODE 8 4 1 Data Display 9 4 2 Water Valve Test 10 4 3 Drain Pump Test 10 4 4 Restart Feature 10 4 5 Recycle Feature 11 4 6 Hot Bowl Flag 11 5 FAULT CODES 11 6 WIRING DIAGRAM...

Page 5: ...ave Water 39 6 gal 150 liters Eco Rinse 27 7 gal 105 liters 1 Deep Rinse 43 5 gal 165 liters 2 Deep Rinse 56 79 gal 215 liters Note Approximate water consumption for a high water level load for each rinse option offered 1 4 Water Fill Temperature Approximate Factory Settings Supply Water Fill Temp Hot 140o F 60 o C Hot Warm 122 o F 50 o C Warm 104 o F 40 o C Warm Cold 95 o F 35 o C Cold Plus 68 o ...

Page 6: ...hine is not in use 1 8 Thermistor NTC type temperature sensor Thermistor Resistance 10 000Ω 77 o F 25o C 1 9 Cabinet Pre painted steel 1 10 Lid ABS plastic co injected 1 11 Top Deck Polypropylene 1 12 Inner Basket Stainless steel Grade 430T Basket base and balance ring Polypropylene The inner bowl on the large machine has a series of small bumps around the base of the inner bowl These bumps are de...

Page 7: ...r Polypropylene 1 16 Fabric Softener Dispenser Dosage 75cc 1 17 Electric Supply Operating Voltage 110 120V AC 60Hz Maximum Current 7 0 amps 1 18 User Information User Guide 420900 Com pact Disk 420353 1 19 Lid Lock Resistance 63Ω 10 68o F 20o C Note Normally low voltage potentially 110V if harness is grounded on the cabinet 1 20 Control Panel Intuitive Eco ...

Page 8: ...ly then will it release the lock The motor is acting like a generator and allows the lock to stay energized under the bowls inertia The chart below shows the stages when the lid is locked In a brown out situation the machine will restart at the start of whatever section of the cycle it was on and continue the wash The lid lock would then be reactivated if it happened to be on a spin cycle 3 SIZE S...

Page 9: ...ed Out Of Balance Over Suds or water still in the machine during spin No Hot Water No Cold Water Agitate Overloaded The MACHINE STATUS screen displays the status of the diverter and the out of balance switch It also displays the size setting of the machine and the thermistor temperature HVDC is for on line testing in the factory Target temp is the temperature selected T is the actual temp of the i...

Page 10: ...reen by the word RESTART highlighted To turn the RESTART feature OFF push the HOME button This will remove the highlight from the word RESTART When the machine is being serviced it is more convenient to turn the RESTART feature OFF This will allow any fault in the system to show up immediately With the RESTART feature on 1 If a fault occurs in the machine the diagnostic system will detect it Howev...

Page 11: ...d as a service aid only and should be OFF in the customer s home To return to normal operation and to return the recycle feature to the factory setting switch the machine off at the wall or disconnect from the mains supply 4 6 Hot Bowl Flag If the machine has been filled with the hot water valve utilized ie warm or hot fill and has not had a cold rinse the electronics will not allow the machine to...

Page 12: ...517793A 12 6 WIRING DIAGRAM ...

Page 13: ...securing the console to the top deck c Tilt the console forward 7 2 Removal Of Display Module a Disconnect the wiring harness from the display module b Remove the 3 screws securing the display module to the console c Using a flat bladed screwdriver push the two top tabs that secure the display module to the facia d When these tabs are clear lift the right hand end of the module and slide in the di...

Page 14: ...517793A 14 Notes ...

Reviews: