ELECTRICAL CONNECTION

PERMANENT CONNECTION (HARD WIRING) 

US only, for Canada it is mandatory to connect  

the range by using cordset with plug supplied.

Units may be hard wired to the power supply. The 
installer must provide approved flexible aluminium 
conduit, 3/4” (19mm) trade size, maximum 6ft (1.8m) 
long. Locate the terminal block on the rear of the unit 
and remove access cover.  

The strain relief bracket orientation must be switched 
in order to accommodate for a permanent wiring 
connection:

1

  Remove the factory supplied power cord with plug.

2

  Remove the 2 screws on the bracket.

3

  Re-secure bracket with the 2 screws so that the  

1 1/8” (29mm) smaller opening is facing down. 
 
 
 
 
 
 
 
 
 
 
 
 

 

The conduit must be installed to the terminal block using 
an approved conduit connector. The free end of the 
conduit must be connected to a junction box provided in 
the electrical supply zone.

Mount a strain relief (not provided) into the 1 1/8” 
(29mm) diameter hole located below the terminal block. 
Wiring for the unit is to be brought into the terminal 
block through the conduit and through the strain 
relief. Make suitable connections to the terminal block 
provided.

Installer — Show the owner the location of the circuit 
breaker. Mark it for easy reference.

4-Wire Connection

1

  Loosen the L1 (black), L2 (red) and neutral (white) screws.

2

  Mount the conduit fitting to the 1 1/8” (29mm) hole in the 

strain relief bracket.

3

  Secure the neutral (white) power lead to the center 

terminal and tighten the screw.

4

  Secure the L1 (black) and the L2 (red) power leads to the 

terminals immediately to the left (L1) and right (L2) of the 
neutral terminal. Tighten the screws. 

5

  Secure the Ground (green)  lead to the green screw 

located to the right of the terminal block using the 
supplied cupped washer. The end of the grounding 
conductor must be retained by the cupped washer.

6

  Check all connections are securely tightened.

7

  Reinstall the Terminal Block cover.

3-Wire Connection (using supplied Ground lead)

1

  Loosen the L1 (black), L2 (red) and neutral (white) 

screws.

2

  Mount the conduit fitting to the 1 1/8” (29mm) hole in 

the strain relief bracket.

3

  Secure the supplied Ground (green) lead to the 

grounding screw to the right of the terminal block. 

4

  Secure the Neutral (white) power lead together with 

the free end of the Ground (green) lead to the center 
terminal. Tighten the screw.  

5

  Secure the L1 (black) and the L2 (red) power leads 

to the terminals immediately to the left (L1) and right 
(L2) of the neutral terminal. Tighten the screws. 

6

  Check all connections are securely tightened.

7

  Reinstall the Terminal Block cover.

1

2

3

Terminal Block

Strain relief bracket

Smaller opening

PE

N

L1

L2

N

L1

L2

PE

PE

N

L1

L2

N

L1

L2

PE

Summary of Contents for OR30SCI

Page 1: ...OR30SDI OR30SCI Induction OR30SDE Glass Ceramic models FREESTANDING COOKER INSTALLATION GUIDE US CA 591507D 10 19...

Page 2: ...liance 5 Model identification 6 Prior to installation 6 Product dimensions 7 Clearance dimensions 8 Fitting the optional backguard 9 Location of electrical supply 9 Ventilation requirements 10 Fitting...

Page 3: ...mestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death Installation WARNING OTE NOTES MATERIALE E FINITURA FACESTOCK PO...

Page 4: ...reach of children as these may cause serious injuries Make sure you recycle the packaging material Before disposing of any appliance make sure that it can no longer be used and that all hazardous part...

Page 5: ...e measure Screwdriver 2 Wrench T handle wrench Tape measure Pencil Adjustable pliers Adjustable wrench Suitable protective gloves Drill Hammer Suitable protective gloves Screwdriver 2 Wrench T handle...

Page 6: ...pping damage If any damage is detected call the shipper and initiate a damage claim Fisher Paykel is not responsible for shipping damage DO NOT discard any packing material until the range has been in...

Page 7: ...908 max 37 5 8 956 B Overall width of range 29 7 8 759 29 7 8 759 C Overall depth of range from front of range to rear of island trim backguard excluding handles and dials 25 1 4 641 25 1 4 641 D Heig...

Page 8: ...nimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or D 24 610mm minimum when bottom of wood or metal cabinet is protected by not less than t...

Page 9: ...rrectly in place The island trim is already fitted to the appliance while the backguard can be purchased as a separate kit If replacing the island trim with the backguard assemble it by using the same...

Page 10: ...ed or air conditioned household air when maximum ventilation is not required Normally the maximum blower speed is only required when grilling or using the self cleaning cycle If a custom hood canopy c...

Page 11: ...to tip the range again to make larger adjustments Fitting the adjustable feet covers optional If using the adjustable feet covers fit these while the range is tipped over FITTING THE ADJUSTABLE FEET 3...

Page 12: ...sure two people carry out this manoeuvre to prevent damage to the adjustable feet Be careful do not lift the range by the oven door handle the hob rail or the cooktop trim as this may damage the appli...

Page 13: ...adjustable bracket to the back of the range centered on the lower edge using the two supplied screws and washers The anti tip bracket has two components the adjustable bracket the stability bracket I...

Page 14: ...the plastic sleeve anchors drill 5 16 8mm diameter holes and insert the supplied anchors before attaching the stability bracket with the screws 4 Slide the range into place ensuring the bolt on the a...

Page 15: ...240V or 120 208V 60Hz AC only electrical supply is available a 50 amp maximum circuit protection is required fused on both sides of the line Replacing the power cord Replacements should only be made b...

Page 16: ...e 4 Wire Connection 1 Loosen the L1 black L2 red and neutral white screws 2 Mount the conduit fitting to the 1 1 8 29mm hole in the strain relief bracket 3 Secure the neutral white power lead to the c...

Page 17: ...lation Company Installation Date OPERATION F F All internal packing materials removed Check inside the oven F F Dials turn correctly and freely F F Oven and cooktop displays are functioning correctly...

Page 18: ......

Page 19: ...18...

Reviews: