Adjusting the Cooktop Burner Minimums
When switching from one type of gas to another, the minimum flow rate must also be correct:
• The flame should not go out even when passing suddenly from maximum to minimum flame.
To regulate the flame follow these instructions:
Semi-rapid Burner (A)
• Light the burner.
• Set the gas valve to
LO
position (minimum rate).
• Remove the dial.
• With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct.
Inside Crown of DUAL Burner (B)
• Light the DUAL burner.
• Set the gas valve to
LO
position (minimum rate of inner crown).
• Remove the dial.
• With a thin screwdriver, turn the regulation screw until adjustment is correct. The screw is accessible via a hole
in the microswitch.
Outside Crown of DUAL Burner (C)
• Light the DUAL burner.
• Set the gas valve to
LO position (minimum rate of outer crown and maximum rate of inner crown).
• Remove the dial.
• With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely
Updated: Thu, 02 Dec 2021 09:44:40 GMT