![Fisher & Paykel OR30SCG4R1 Manual Download Page 3](http://html1.mh-extra.com/html/fisher-and-paykel/or30scg4r1/or30scg4r1_manual_2296010003.webp)
To set the Pressure Regulator
1. Unscrew the regulator cover.
2. Unscrew the
C
component, reverse and screw it according to the LP/PROPANE (or NATURAL GAS)
regulation.
To Replace the Storage/Warming Drawer
1. Insert the storage/warming drawer guides into the range guides.
2. Gently close the drawer completely; the safety catches will automatically hook into place.
Injectors Table
Burners
Nominal Power
Reduced
Power
LP/Propane 11”
(279.4mm) W.C.P
Natural Gas 4”
(101.6mm) W.C.P.
BTU/HR
BTU/HR
Ø Injector [1/100 MM]
Ø Injector [1/100 MM]
Semirapid (SR)
7600 (LP/
Propane Gas)
1800
78
-
8000 (Natural
Gas)
1800
-
136
Dual
(D)
Inner
crown
2800
1
1100
1
47
3
80
3
Full
burner
18000
2
6500
2
79 (x2)
4
135 (x2)
4
OR30 Gas Models Only
Oven burner
14000
2400
109
190
Updated: Thu, 02 Dec 2021 09:44:40 GMT