Cleaning the Motor Assembly
This area only needs to be cleaned under certain fault conditions ie F2. If you have an integrated product the fault code
will appear on the secondary control panel, refer to the section on Fault Codes, it will explain under which conditions to
clean the motor assembly.
1
Follow the above instructions for the removal of the drain filter, spray arm and filter plate.
2
Turn the rotor-locking ring counter clockwise and lift out. Once the motor assembly is lifted up, check the cavity
for any foreign matter like bones or seeds and remove.
3
Replace the motor assembly back into the small cavity in the DishDrawer
®
. Turn the motor assembly clockwise
about 1/8 of a turn to lock into position. The arrows ( >) on the rotor locking ring and the motor housing must align
with each other The motor assembly should not be able to be lifted up freely. Carefully replace all the other parts
back into the DishDrawer
®
.
Rotor Locking Ring
Impeller
Heater Plate