- 3 -
1.2
Specialised Tools
For servicing this product Specialised tools are required.
1.2.1
Static Strap:
To be used as ESD protection when replacing or handling
electronic components.
1.2.2
Down Load Pen Connection: P/N 425930C.
To be used to retrieve data from the electronic controller along
with the diagnostic program on your laptop.
1.2.3
Down Load Serial Connection: P/N 425376C.
To be used to retrieve and download data from the electronic
controller along with the diagnostic program on your laptop.
1.2.4
Perspex Test Lid: P/N 525826.
To be used on the drawer while extended to observe water fill,
wash and drain operations.
1.2.5
Air Gauge and Plumbing. P/N 525819.
To be used to measure the air pressure in the lid seal and
plumbing.