background image

24

23

FINAL CHECKLIST

TROUBLESHOOTING

Spray arms

Check all parts are installed.

Ensure product is level, securely fastened to the cabinetry and opens and 

closes freely. The drawer must be free to fully close with no resistance from the 

cabinetry.

Ensure inlet hose to water supply has supplied rubber washer fitted, and that 

it’s tightened a further half turn after seal contact.

Ensure any knockouts or plugs in drain connection have been drilled out and 

drain connection has been made.

The drain hose joiner must not support the weight of excess hose material. 

Keep drain hose as fully extended as possible to prevent sagging. Any excess 

length of drain hose should be kept on the dishwasher side of the highloop.

If connecting the drain hose to the sink trap, ensure the Highloop is a minimum 

6” (150 mm) higher than the drain hose joiner.

Ensure any packaging or tape securing the racks is removed from the drawer.

Turn on the power and water supplies, then open the drawer. You should hear a 

beep and see a program indicator light up on the internal control panel.

Check the spray arms are in place and free to rotate.

Add three cups of water into the drawer. Press 

 on the internal control panel 

until the indicator of the ‘Rinse’ program lights up. Close the drawer and press 

 to start the program.

After the Rinse program has finished, ensure the dishwasher has run and 

drained correctly.

Check water supply and drainage connection for leakage.

 

Excessive water remaining above the filter plate, after the rinse cycle

 

Check for a kinked drain hose or blocked waste connection, highloop not 
properly installed or drain hose not routed correctly.

 

No water supply (This is displayed as a ‘U1’ fault -- see section ‘If there is a 
fault’ in the User guide for how to recognise this fault on models without a 
display.)

 

Check water is connected and turned on.

 

The dishwasher is beeping continuously

 

There is a fault. See section ‘If there is a fault’ in the User guide for further 
information and instructions.

 

No program indicator lights up when the drawer is opened

 

Ensure power is connected and is switched on. If it is and still no indicator 
lights up, see the ‘Preference options’ section of the ‘Quick start guide’. An 
option called ‘Open drawer auto power-on’ may need to be turned on.

 

Water around water supply and drainage connections 

 

Check connections, existing plumbing and hoses for leaks. Check rubber 
washer and hose clamp are correctly fitted.

 

If product is tipping

 

Ensure the product is secured to the cabinetry. 

 

If front panels are misaligned

 

Check and relevel product. Check the cabinetry is square. Check and adjust 
front panel alignment if necessary.

 

Drawer doesn’t close properly

 

Ensure nothing is obstructing the drawer from closing properly eg sound 
insulation, hoses or drawer latches.

  If a problem occurs, consult the ‘Troubleshooting’ or ‘Fault codes’ section of 

the User guide.

 

If after checking these points you still need assistance, please refer to the 
Service & Warranty book for warranty details and your nearest Authorized 
Service Center, or contact us through our website, listed below.

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change 
at any time. For current details about model and specification availability in your country, please 
visit our local website listed at the end of this document or contact your local Fisher & Paykel 
dealer.

www.fi sherpaykel.com      www.fi sherpaykel.ca

Summary of Contents for DD36SDFTX2

Page 1: ...US CA 590208C 08 12 DD36SDFTX2 Designer DD36STI2 Integrated models INSTALLATION INSTRUCTIONS DishDrawerTM dishwasher ...

Page 2: ...stallation the Installer must perform the Final Checklist Remove all packaging materials supplied with the dishwasher This dishwasher is manufactured for indoor use only Ensure all water connections are turned OFF It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations The dishwasher MUST be installed to allow for future remo...

Page 3: ...ces you must use a Drain Hose Extension Kit P N 525798 which will extend the drain hoses by 11 10 3 6m The kit is available from the nearest Fisher Paykel Authorized Service Center or Toll free 1 888 936 7872 or www fisherpaykel com Edge Protector 1 If the services hole is through a metal partition the hole must be protected with the Edge protector supplied to prevent damage to the power cord or h...

Page 4: ...t panel 21 553 21 553 E maximum extension of drawer excl handle 21 7 16 545 21 7 16 545 2 F depth of front panel excl handle 11 16 18 5 8 13 16 16 20 G height1 of chassis 18 1 16 458 18 1 16 458 H depth of handle 1 5 8 41 n a I height of front panel 18 470 18 476 3 J height of ventilation gap below front panel 5 16 8 min 1 16 2 K height from top of handle to top of front panel 2 64 n a 1 includes1...

Page 5: ...0 18 7 8 480 M inside height of cavity 18 1 8 460 min 18 1 8 460 N inside width of cavity 34 864 34 864 O overall width of cabinetry 35 7 16 900 35 7 16 900 P inside depth of cavity min 22 1 16 560 min 22 1 16 560 Recommended min 13 mm clearance from a corner cupboard min 1 16 2 mm clearance to adjacent cupboard door Important Ensure correct chassis position In order for product to function cabine...

Page 6: ... mm HEIGHT OF PANEL 2x FRONT PANEL SPECIFICATIONS 5 8 13 16 16 20 mm panel thickness Maximum weight of panel 20 lb 9 kg Adequately sealed to withstand moisture 122O F 50O C 80 RH Because of it being a hot and wet environment generally the back and sides of the panel should be completely sealed with a waterproof vapor barrier ie polyurethane to prevent damage to the panel The back of the panel incl...

Page 7: ...e the release tabs on both sides are reset fully Ensure the drawer is now rotated clockwise back 2 100 mm 1 3 Product may move Mark chassis position on cavity Access cover Press the release tabs in on either side and push back to release drawer from runners 5 6 7 8 9 9 10 14 15 16 17 18 11 12 12 13 8 4 100mm 4 5 To prevent kinked hoses we recommend rotating the drawer counter clockwise and resting...

Page 8: ...Pa 145 psi Min 0 1 MPa 14 5 psi Models without water softener Max 1 MPa 145 psi Min 0 03 MPa 4 3 psi Important The power outlet must be located in a cabinet adjacent to the dishwasher cavity 110 120 VAC max 15 A min 7 7 8 200 mm 3 8 10mm 1 16 2mm max 5 7 8 150 mm ømax 1 38 mm Services hole Can be located either side of dishwasher preferably at the bottom of the cavity as shown If adequate clearanc...

Page 9: ...her VENTHOSE VENTHOSE DRAINHOSE INLETHOSE POWERCORD DRAINHOSE INLET HOSE POWERCORD Servicescanbelocated eithersideofdishwasher Shelf cutouts Shelf cutouts The ø 2 3 8 60 mm services hole for the hoses should be enlarged to accomodate the extra venting hose by cutting out some material from the bottom corner If the services holes are through metal ensure you fit the supplied Edge Protector around t...

Page 10: ...t hand side Drain hose 78 2000 mm Inlet hose 64 1650 mm Venting hose 49 13 16 1265 mm Venting hose 75 13 16 1925 mm Integrated models only Integrated models only Power cord excl plug 29 750 mm Power cord excl plug 15 400 mm Drain hose 59 1 16 1500 mm Inlet hose 37 3 8 950 mm ...

Page 11: ...11 ...

Page 12: ...Ensure they re securely fitted before sliding product into cavity A The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and B bracket must match B slot Check that the fitted elbow is rotated left or right depending on the direction of the routing then ensure the venting hose is securely attached to it NOW CHOOSE WHICH INSTALLATION METHOD a or ...

Page 13: ...he chassis Vent Hose Integrated models only vent either through same cabinet or adjacent cabinet as per step 7b or 7c 1 3 2 Open the drawer halfway Using a flat bladed screwdriver prise the gray rubber plug out of the trim moulding Replace the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a small Philips screwdriver screw...

Page 14: ... pull through hoses and cord ensuring they don t get kinked or twisted Important If product cannot be pushed in far enough pull out again and rearrange hoses and cord Do not use excessive force as doing so may squash the hoses and lead to incorrect operation Important Ensure correct chassis position In order for product to function cabinetry must not block the drawer front from closing hard agains...

Page 15: ...s back in Product may move Mark chassis position on cavity 2 1 After routing the vent hose through and out the hole cutout attach and secure the vent by tightening the four screws provided Airflow 5 5 1 2 3 4 4 100 mm 1 2 2 The product has three pairs of fixing points Refer to 2 PARTS SUPPLIED for relevant parts Ensure the sound insulation is repositioned correctly a pair of fixing holes either si...

Page 16: ...tinuing ensure that the product is disconnected from the power supply Failure to follow this warning may result in electrical shock injury or fire WARNING WARNING Electrical Shock Hazard To ground earth the panel bracket connect the ground earth wire from the product to one of the tabs Any custom metal compo nent e g handle that extends past the rubber door seal must be grounded earthed too Failur...

Page 17: ...rotate the panel up or down to align the gaps in your cabinetry Repeat on the other side if necessary The panel has a maximum travel of 1 16 2 mm up or down Important Integratedmodels Ensurethatyoumaintainaminimumof1 16 2mm ventilationgapbelowthepanel Designermodels Ensureyoumaintainaminimumof5 16 8mm ventilationgapbelowthepanel or 1 16 2 mm ...

Page 18: ...rain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 34 750 882 5 mm min R 8 200 mm min R 8 200 mm min R 8 200 mm 1 38 mm max 4 120mm 29 34 750 882 5 mm 29 34 750 882 5 mm Supplied drain hose joiner Ø 19 mm waste tee HIGHLOOP min 6 150 mm 21 21 21 37 3 8 950 mm Max height to top of Air Break countertop or wall mounted Dishwasher usi...

Page 19: ...O HOT WATER SWITCH PRODUCT ON 21 22 3 4 Ensure the supplied rubber washer is fitted inside the coupling Tighten coupling with wrench 180o No leaks 1 2 Important Ensurethatdrainconnectionwillcomplywithlocalplumbingregulations ...

Page 20: ...uted correctly No water supply This is displayed as a U1 fault see section If there is a fault in the User guide for how to recognise this fault on models without a display Check water is connected and turned on The dishwasher is beeping continuously There is a fault See section If there is a fault in the User guide for further information and instructions No program indicator lights up when the d...

Reviews: