16
LOW FLAME ADJUSTMENT
1
3
4
2
Remove the dial.
While holding the valve shaft with
pliers, insert a flat-tipped screwdriver
into the shaft and, while viewing the
burner, adjust to a minimum stable
flame.
Push in and hold the selected dial
for 2 seconds before turning to
HI
.
Hold for 10 seconds to light the
selected burner.
Turn the control dial counter-
clockwise to the lowest setting.
BEZEL FRONT VIEW
The valves on the double side burner/griddle unit feature an adjustable low setting. Due
to fluctuations in gas pressure, or heating value you may feel it necessary to increase or
decrease gas flow in the low position. If the gas type has been converted from natural to LP
or vice-versa, the low flame setting must be reviewed and adjusted.