background image

4

INSTALLATION CONSIDERATIONS

Please ensure the following:

 

z

A suitable disconnection switch is incorporated in the permanent wiring, mounted and 
positioned to comply with the local wiring rules and regulations.  A means of disconnection 
with at least a 3mm air gap contact separation in all poles must be incorporated into the 
fixed wiring in accordance with the wiring rules, unless the local wiring rules allow for 
alternative means.

 

z

The benchtop is made of a heat resistant material.

 

z

There is adequate flow of cool air from the cabinetry to the base of the cooktop. You 
may ventilate from adjacent cupboards, but ensure that the available air supply will not 
be restricted.

 

z

The ventilation area must be equivalent to 40cm2 Refer to 'Clearances'.

 

z

The power supply cable is not accessible through cupboard doors or drawers. 

 

z

The isolating switch is easily accessible by the customer.

 

z

You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall 
surfaces surrounding the cooktop.

 

z

The cooktop will not be installed directly above a dishwasher, fridge, freezer, steam oven, 
washing machine or clothes dryer, as the humidity may damage the cooktop electronics. 

 

z

The installation will comply with all regulations relating to the discharge of air, clearance 
requirements and other applicable standards and regulations.

 

z

You consult local building authorities and by-laws if in doubt regarding installation.

 

z

The installation will comply with all regulations relating to the discharge of air.

Please ensure the following:

 

z

Flush mounting or sealing this appliance into the bench with silicone or glue may make 
future servicing difficult. Fisher & Paykel will not be liable for any costs associated with 
removing or replacing a sealed-in appliance, nor for repairing any damage that may be 
incurred by doing this. 

 

z

Seal exposed bare edges of the cutout with an oil-based paint or moisture-proof 
polyurethane to prevent possible moisture creeping between the cooktop trim and 
the benchtop.

 

z

Take extreme care not to chip, crack, or break the top glass surfaces during installation. 
A heavy metal tool or part accidentally dropped on the glass could damage it. 

 

z

If, after following the instructions given, correct performance cannot be achieved, please 
contact your nearest Fisher & Paykel Authorised Service Centre, Customer Care, or contact 
us through our local website listed at the end of this document.

WARNING!

The owner carries all risk for flush mounting the cooktop. The owner must ensure the 

cooktop has been cut out from the countertop before servicing can be carried out. 

Fisher & Paykel will not be liable for any costs associated with removing or replacing a flush-

mounted and/or sealed-in product, nor for repairing any damage that may be incurred by 

doing this.

BEFORE INSTALLATION

DURING INSTALLATION

Summary of Contents for CID834RDTB4

Page 1: ...MINIMAL CID834RDTB4 DOWNDRAFT INDUCTION COOKTOP INSTALLATION GUIDE UK IE...

Page 2: ......

Page 3: ...to property and may invalidate any warranty or liability claims z Do not modify this appliance z Do not use or store flammable materials on or near this appliance z Packing elements eg plastic bags po...

Page 4: ...e standards and regulations z You consult local building authorities and by laws if in doubt regarding installation z The installation will comply with all regulations relating to the discharge of air...

Page 5: ...below accessory kits can be purchased separately to expand venting options z To purchase accessory kits visit fisherpaykel com PARTS SUPPLIED OPTIONAL ACCESSORY KITS Wrench Recirculation filter housin...

Page 6: ...op glass 15 L Height of venting 500 899 M Height of venting outlet 37 N Width of venting outlet 340 O Width of ducting 222 P Depth of ducting 89 Q Height of horizontal ducting 59 R Depth of venting 38...

Page 7: ...horizontal elbow 257 C Overall depth of horizontal elbow 257 D Overall height of ducting 55 E Overall width of ducting 218 F Overall depth of ducting 1000 G Overall height of connector 58 H Overall wi...

Page 8: ...B e c c f A d b d h g CUTOUT DIMENSIONS MM A Overall height of routered recess 6 B Overall width of routered recess 835 C Overall depth of routered recess 520 D Overall width of cutout 807 E Overall...

Page 9: ...to 40cm2 Combustible surface definition any materials of a building structure or decorative structure made of wood compressed paper plant fibres vinyl plastic or other materials that are capable of tr...

Page 10: ...pace of 140mm is required at the rear of the cabinetry to house the ducting components Alternately if vertical ducting is to pass through any shelving ensure a cutout of 232mm x 100mm has been created...

Page 11: ...CONNECTION junction box BASE 1 3 5 2 L N PE 4 1 3 5 2 L1 L2 N PE 4 1 3 5 2 L1 L3 L2 N PE 4 1 3 5 2 L N PE 4 1 3 5 2 L1 L2 N PE 4 1 3 5 2 L1 L3 L2 N PE 4 1 3 5 2 L N PE 4 1 3 5 2 L1 L2 N PE 4 1 3 5 2 L...

Page 12: ...al ducting to the required length and slot into the elbow Tape to secure 4 Fit the outlet to the ducting and tape to secure Align the outlet to the toe kick panel and adjust the height to suit To incr...

Page 13: ...before rotating and lowering it into the cutout Tape the ducting to secure Attach the four side clips to the cooktop chassis Ensure the clips are oriented correctly Slot the two filter housing compon...

Page 14: ...ecess Apply silicone in the gap between countertop and cooktop Wipe off any excess silicone INSTALL COOKTOP FLUSH adhesive 3 4 Slot the two filter housing components together before fitting to the rea...

Page 15: ...a constant flow of cool air from the cabinetry to the base of the cooktop Cooktop is securely clamped Basic operation has been demonstrated to the customer VENTILATION Ensure all ducting components a...

Page 16: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...

Reviews: