VENTING CLEARANCES
Oven* with cooling fan
Drawer or other obstruction
This cooktop requires adequate supply of cool air to fully function. The base of the cooktop
must have direct unrestricted ventilation to the room where the cooktop is installed. There
must be a 4mm air gap at the front of the cooktop.
CLEARANCE DIMENSIONS
MM
A
Minimum ventiliation gap at the front of the cooktop
4
B
Minimum clearance from cooktop to drawer or other obstruction
65
C
Minimum ventiliation gap at the rear of the cooktop
20
D
Minimum diameter of cooling air hole
50
CLEARANCE DIMENSIONS
MM
A
Minimum ventilation gap at the front of the cooktop
4
B
Minimum ventilation gap at the rear of the cooktop
20
C
Minimum diameter of cooling air hole
50
*Some ovens require installation in a sealed box. Please refer to your oven installation guide for more information.
A
A
B
D
C
C
B
DRAWER OR OTHER OBSTRUCTION
OVEN WITH COOLING FAN
12