Fisher & Paykel CG602 Series Installation Instructions Manual Download Page 4

4

a

e

c

d

b

f

g

Clearances

a

600 mm minimum from top of trivet to rangehood.
750 mm minimum from top of trivet to overhead exhaust fan.  (Fisher & Paykel splashbacks are 
750 mm high).

b

600 mm minimum from top of trivet to downward facing combustable surface.  (450 mm 
minimum if protected by tiles or fire resistant materials).

CG602 SERIES

CG902 SERIES

CG913 SERIES

c

Clearance from side edge of 
product to any combustible surface

130 mm

120 mm

80 mm

d

Clearance from rear edge of 
product to any combustible surface

100 mm

90 mm

90 mm

Clearance from rear edge of 
product to any non-combustible 
surface

10 mm

10 mm

10 mm

e

Clearance below benchtop to any 
combustible surface

60 mm

60 mm

81 mm

Clearance below benchtop to 
F&P DishDrawer® or F&P oven

45 mm

45 mm

81 mm

f

 

Ensure there is an earthed power outlet within 900 mm of the rear right-hand corner of the 
product.  When used with a flexible hose, the connector on the wall should be between 800 
mm to 850 mm above the floor and in the region outside the width of the appliance to a 
distance of 250 mm.  This should be accessible with the appliance installed.

g

 

When protecting a wall with non-combustible material it must be at least 150 mm high.

Summary of Contents for CG602 Series

Page 1: ...599257 A 01 2005 NZ AU Installation Instructions NZ AU CG913 SERIES CG602 SERIES CG902 SERIES...

Page 2: ...ation available to the person responsible for installing the product as it could reduce your installation costs These products are registered in New Zealand at www ess govt nz and in Australia with AG...

Page 3: ...s CG902 series CG913 series D Width 560 558 562 870 846 872 870 860 882 E Depth 490 485 495 494 478 501 494 486 524 F Radius R10 R10 R10 G 30 30 30 H 40 50 35 J Clearance to nearest combustible servic...

Page 4: ...ble surface 100 mm 90 mm 90 mm Clearance from rear edge of product to any non combustible surface 10 mm 10 mm 10 mm e Clearance below benchtop to any combustible surface 60 mm 60 mm 81 mm Clearance be...

Page 5: ...ll cope with a bench thickness of 20 50 mm For benchtops thicker than 50 mm recess the underside to a thickness of 20 50 mm Gas Supply Connection This cooktop is supplied set up for Natural Gas but is...

Page 6: ...heck insulation resistance and earth continuity Natural Gas For Natural Gas usage the gas supply is connected to the regulator which is supplied loose with a built in test point 1kPa 4 WG and the inle...

Page 7: ...knob 5 When the setting is right check regulation by quickly rotating the knob from the maximum to the minimum delivery position The flame must not go out figure 6 12 Turn on main electrical supply an...

Page 8: ...front 0 85 mm 3 7 MJ h 0 55 mm 4 1 MJ h Semi Rapid Burner LH RH rear 1 3 mm 7 9 MJ h 0 80 mm 7 9 MJ h Fish Burner Centre 1 45 mm 10 MJ h 0 85 mm 10 MJ h Wok Burner LH front 1 8 mm 15 MJ h 1 05 mm 15...