background image

1

IMPORTANT!  

 

SAVE THESE INSTRUCTIONS

The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our 
website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

  IMPORTANT SAFETY INSTRUCTIONS

 

This appliance shall be installed in accordance with the installation requirements of the 
local gas authority or the appropriate installation code or in the absence of local codes 
with the latest National Fuel Gas Code NFPA 54/ANSI Z223.1 or CAN/CSA B149.1,2 
(Canada). Local building and electrical codes must be adhered to.

 

Electrical installation must be in accordance with the National Electrical Code, ANSI/
NFPA70 - latest edition or CSA C22.1 (Canada) and/or local codes.

 

Installation in manufactured (mobile) home: installation must conform with the 
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly 
the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 
280)] or, when such standard is not applicable, the Standard for Manufactured Home 
Installations, ANSI/NFPA 225, or with local codes where applicable.

 

Installation in Recreational Park Trailers: installation must conform with state or other 
codes or, in the absence of such codes, with the Standard for Recreational Park Trailers, 
ANSI A119.5.

 

Do not remove permanently affixed labels, warnings, or plates from the product. This 
may void the warranty.

 

Flexible appliance connectors shall meet the requirements of ANSI Z21.24 and State 
Boards. They shall not exceed 35 1/2 inches (900 mm) in length. In order to avoid hazard, 
these appliances must be installed according to these instructions.

 

This appliance must be installed by an authorized person (Warning: this appliance must 
be installed by a licensed plumber or gas fitter when within the Commonwealth of 
Massachusetts).

 

Please make this information available to the person installing the appliance as it could 
reduce your installation costs.

 

Please leave these instructions with the appliance. Inform the customer to retain for 
future reference and for the local inspectors’ use.

 

Failure to install the appliance correctly could invalidate any warranty or liability claims.

 

Leak testing of the appliance shall be conducted according to the manufacturer’s 
instructions.
Only genuine replacement parts may be used for servicing the appliance. These are 
available from your nearest Fisher & Paykel Service Center.

Before you install the appliance, please make sure that
 

 

the local distribution conditions (nature of gas and pressure) and the adjustment of the 
appliance are compatible. For adjustment conditions for this appliance, see ‘Gas rate 
summary’ under step 3. 

 

a suitable isolating switch is incorporated in the fixed wiring in an acceptable position.

 

the appliance is connected to a power outlet that is electrically grounded in accordance 
with local codes or in the absence of local codes, with the National Electric Code ANSI/
NFPA 70 or CSA C22.2 (Canada).

 

there is a power outlet (110-120V 60Hz) within reach of the appliance cable (35 1/2” (900 
mm) from the center rear of the appliance). This must be accessible after installation. The 
mains power supply cable should not touch any metal parts.

 

the countertop is square and level and no structural members interfere with space 
requirements

 

the countertop is made of heat-resistant material.

 

you take note of the following recommended non-combustible materials: 1/4” (6 mm) flame 
retardant millboard covered with not less than No. 28 MSG sheet steel, 1/32” (0.4 mm) 
stainless steel, 

 

 1/32” (0.6 mm) aluminum or 1/32” (0.5 mm) copper.

 

the gas shut-off valve is accessible after installation.

 

if the power supply cable is damaged, it is replaced only by the special cable: Part no. 
534901 Trml Block-flex Assy CG901 NZ US, obtainable from authorized Fisher & Paykel 
Service Agents.

 

NOTE: 
As servicing requires removing of the cooktop from the countertop we do not recommend 
flush mounting. To the fullest extent permissible by law, the owner carries all risk for flush 
mounting of the cooktop. The owner must ensure the cooktop has been cut out from the 
benchtop before servicing can be carried out. Fisher & Paykel will not be liable for any 
costs associated with removing or replacing a flush-mounted and/or sealed-in product, 
nor for repairing any damage that may be incurred by doing this. Fisher & Paykel does not 
exclude any statutory liability it may have and which by law cannot be excluded, because of 
the giving of this notice.

1

   SAFETY AND WARNINGS

 WARNING!

Electrical Shock Hazard
Disconnect product from the mains power supply before servicing. This 
appliance is equipped with a three-prong grounding plug for your
protection against shock hazard and should be plugged directly into a
properly grounded power outlet. Do not under any circumstances cut or
remove the grounding prong from this plug. 
Failure to follow this advice may result in electrical shock or death.

 WARNING!

Cut Hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.

!

!

Summary of Contents for CG365DW Series

Page 1: ...Gas Cooktop CG365DW models US CA INSTALLATION INSTRUCTIONS 590686A 03 14 www sherpaykel com...

Page 2: ...are available from your nearest Fisher Paykel Service Center Before you install the appliance please make sure that the local distribution conditions nature of gas and pressure and the adjustment of...

Page 3: ...ustomer care or refer to the website listed at the back of this document CG365DW SEMI RAPID SEMI RAPID RAPID DUAL WOK AUX US CA INJECTOR ORIFICE MM NOMINAL RATING BTU HR INJECTOR ORIFICE MM NOMINAL RA...

Page 4: ...6 77 B Overall width of product 35 1 2 900 C Overall depth of product 20 7 8 530 D Height of chassis below top of counter 2 15 16 74 E Width of chassis 33 5 8 854 F Depth of chassis 19 1 8 485 G Overa...

Page 5: ...pth of overhead cabinetry 13 330 G Minimum distance between overhead cabinets installed to either side of productt 36 915 H Minimum vertical distance between counter and cabinet extending above the co...

Page 6: ...l depth of routered recess 21 1 16 535 HI Depth of cutout 19 7 16 494 I Corner radius of cutout max 3 8 10 J Corner radius of routered recess max 3 16 5 K Height of routered recess 1 8 3 L Distance fr...

Page 7: ...s not leak underneath the steel edge A ROUTER THE COUNTERTOP TO THE SPECIFIED DEPTH D APPLY SILICONE B FIT THE CLAMPING BRACKETS E WIPE OFF EXCESS SILICONE C MASK OFF THE AREA TO BE SILICONED F IF REM...

Page 8: ...6 DISCARD PACKAGING 7 FIT THE NIPPLE AND WASHER 8 LOWER GENTLY INTO THE CUTOUT Nipple NPT thread Recycle responsibly IMPORTANT Use gas tape to seal the connection Model may vary from illustrations sho...

Page 9: ...st be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance In Massachusetts such shut off devices should be...

Page 10: ...he gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures at or less than 1 2 psi 3 5 kPa Maximum inlet...

Page 11: ...correctly light each burner by itself then all burners in combination Check for a well defined blue flame without any yellow tipping If any abnormality is evident check that the components of the bur...

Page 12: ...ure Have you affixed the supplied duplicate data plate label on an adjacent surface accessible to the customer Is the cooktop grounded Check that the power supply cord is NOT touching the cooktop OPER...

Page 13: ...12...

Page 14: ...Surface de cuisson au gaz Mod les CG365DW US CA INSTRUCTIONS D INSTALLATION 590686A 03 14 www sherpaykel com...

Page 15: ...Fisher Paykel dans votre r gion Avant d installer l appareil assurez vous que les conditions de distribution locales nature du gaz et pression et le r glage de l appareil sont compatibles Pour conna t...

Page 16: ...t autoris ou l assistance la client le ou consultez notre site Web l adresse indiqu e l arri re de ce document CG365DW SEMI RAPIDE SEMI RAPIDE RAPIDE DOUBLE POUR WOK AUXILIAIRE US CA ORIFICE D INJECTI...

Page 17: ...duit 35 1 2 po 900 C Profondeur hors tout du produit 20 7 8 po 530 D Hauteur du ch ssis sous la surface du comptoir 2 15 16 po 74 E Largeur du ch ssis 33 5 8 po 854 F Profondeur du ch ssis 19 1 8 po 4...

Page 18: ...ndues 13 po 330 G Distance minimale entre les armoires suspendues install es des deux c t s du produit 36 po 915 H Distance verticale minimale entre le comptoir et une armoire au dessus du comptoir 18...

Page 19: ...16 po 535 HI Profondeur de l ouverture 19 7 16 po 494 I Rayon du coin de l ouverture max 3 8 po 10 J Rayon du coin de la cavit max 3 16 po 5 K Hauteur de la cavit 1 8 po 3 L Distance entre la surface...

Page 20: ...rebord en acier A TOUPILLEZ LE COMPTOIR LA PROFONDEUR SP CI D APPLIQUEZ LA SILICONE B INSTALLEZ LES SUPPORTS DE RETENUE E ESSUYEZ L EXC DENT DE SILICONE C MASQUEZ LA SECTION SUR LAQUELLE LA SILICONE D...

Page 21: ...CORD ET LA RONDELLE 8 D POSEZ L APPAREIL DOUCEMENT DANS L OUVERTURE Raccord letage NPT de po Recyclez de fa on responsable IMPORTANT Utilisez du ruban tanche au gaz pour sceller le raccordement Le mod...

Page 22: ...installer un robinet d arr t manuel dans un endroit accessible de la canalisation externe de l appareil pour pouvoir ouvrir ou couper l alimentation en gaz l appareil au Massachusetts de tels disposi...

Page 23: ...gaz pendant toute v rification de pression de la tuyauterie d alimentation alors que la pression d essai est gale ou inf rieure 1 2 psi 3 5 kPa Pression d admission maximale de l alimentation en gaz...

Page 24: ...allumez chaque br leur individuellement puis tous les br leurs simultan ment V rifiez si l appareil produit une flamme bleu clair bien d finie sans pointe jaune Si vous constatez un fonctionnement ano...

Page 25: ...on ad quate Avez vous appos le double de l tiquette signal tique fourni sur une surface adjacente accessible au client La surface de cuisson est elle mise la terre Assurez vous que le c ble d alimenta...

Page 26: ...25...

Reviews: