![Fisher & Paykel CG365D Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/fisher-and-paykel/cg365d/cg365d_installation-instructions-manual_2295192005.webp)
5
5
CLEARANCE DIMENSIONS
Clearance dimensions
(mm)
C
G365D
A
minimum clearance from left edge of product to nearest vertical surface
5 1⁄8” (130)
B
minimum clearance from right edge of product to nearest vertical surface
4 ½
” (115)
C
minimum clearance from rear edge of product to:
nearest combustible surface
nearest non-combustible surface*
6 5⁄16” (160)
less than
1 ¾
” (45)
D
minimum clearance from front edge of counter to front edge of product
1 ¼
” (32)
E
minimum clearance from cooking surface to combustible surface centered above the cooking surface
36 ” (915)
F
maximum overall depth of overhead cabinetry
13 ” (330)
G
minimum distance between overhead cabinets installed to either side of product
36 ” (915)
H
minimum vertical distance between counter and cabinet extending above the counter
18 ” (457)
I
minimum clearance below top of countertop to:
nearest combustible surface
F&P oven or nearest non-combustible surface
2 ¾
” (70)
2 9⁄16” (65)
J
maximum distance from the center of the product to the nearest grounded power outlet.
The power supply cable must not touch any hot metal surfaces.
35 ½
” (900)
* Recommended non-combustible materials are: 1/4” (6 mm) fl ame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015” (0.4 mm) stainless steel,
0.024” (0.6 mm) aluminum or 0.020” (0.5 mm) copper.
FRONT
ISO
E
G
H
J
I
A
F
B
C
D