PARTS SUPPLIED
2
Small pan support (1)
Wok stand (1)
Fibre washers (1)
Elbow 3/8 “ NPT
external thread (1)
Clamping
brackets (4)
and screws (4)
Regulator (1)
High Altitude Installations
For installations above 3000’ conversion kits are required:
3,000-6,000’
534695 KIT HI ALT NG
534697 KIT HI ALT LP
6000’+
534696 KIT HI ALT NG
534698 KIT HI ALT LP
Contact your authorized dealer, customer care or refer to
the website listed at the back of this document.
3
GAS RATE SUMMARY
CG365D
SEMI-RAPID
SEMI-RAPID
RAPID
DUAL WOK
AUX
US CA
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
Injec
tor orific
e (mm)
Nominal rating (B
TU/hr)
NG 4” H2O
(0.15 psi)*
LP 11” H2O
(0.39 psi)*
AUX
SEMI-RAPID
RAPID
DUAL WOK
NG
LP
NG
LP
NG
LP
NG
LP
CG365D
0.9
3500
0.55
3500
1.40
8500
0.75
6700
1.65
11,500
0.98
11,500
1.50
1.50
0.70
19,000
0.83
0.83
0.50
19,000
Foam tape (1)