Fisher & Paykel CDV3-365 Installation Manual Download Page 3

3

SAFETY AND WARNINGS

!

 WARNING!

Electric Shock Hazard 

Failure to follow this advice may result in 

electrical shock or death.

•  Before carrying out any work on the electrical 

section of the appliance, it must be disconnected 

from the mains electricity supply.

•  Connection to a good ground wiring system is 

absolutely essential and mandatory. 

•  Alterations to the domestic wiring system must 

only be made by a qualified electrician.

!

 WARNING!

Cut Hazard

Failure to use caution could result in injury.

•  Take care: some edges are sharp.

READ AND SAVE THIS GUIDE

WARNING!

To reduce the risk of fire, injury to persons or damage when using the appliance, follow the 

important safety instructions listed below. Read all the guidance before using the appliance. 

Servicing

 

z

Do not repair or replace any part of the appliance unless specifically recommended in 

the user guide. All other servicing should be undertaken be a Fisher & Paykel trained and 

supported service technician or qualified person.

 

z

Technicians must disconnect the power supply before servicing this appliance.

 

z

Please make this information available to the person installing the appliance

 

z

This appliance must be installed and connected to the mains power supply only by a 

suitably qualified person according to these installation instructions and in compliance 

with any applicable local building and electricity regulations. Failure to install the 

appliance correctly could invalidate any warranty or liability claims.

Gas Requirements

 

z

Be sure that the unit being installed is set up for the kind of gas being used. The 

gas rangetop is shipped from the factory set and adjusted for Natural Gas or LP (propane), 

depending on the specific model ordered. Verify that the rangetop is compatible with the 

gas at the installation site before proceeding further. 

 

z

Return cooktop to dealer if the unit is not set for site gas supply.

General

 

z

The appliance must not be installed behind a decorative door in order to avoid 

overheating.

 

z

The cooktop must be grounded.

 

z

Installation must comply with your local building and electricity regulations.

 

z

Ensure the installer shows the customer where the gas supply shut-off valve is located.

 

z

A circuit breaker is recommended.

 

z

If the power supply cable is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified person in order to avoid a hazard.

 

z

Do not use adaptors, reducers or branching devices to connect the oven to 

the mains electricity supply, as they can cause overheating and burning.

 

z

Improper installation, adjustment alteration, service or maintenance can cause property 

damage, injury or death. Read the installation, operating and maintenance instructions 

thoroughly before using, installing or servicing this appliance.

 

z

DO NOT obstruct the flow of combustion or ventilation air to the appliance. 

Be sure a fresh air supply is available.

 

z

Check local building codes for the proper method of cooktop installation. Local codes 

vary. Installation, electrical connections, and grounding must comply with all applicable 

codes. In the absence of local codes, the cooktop should be installed in accordance with 

the latest edition of National Fuel Gas Code ANSI Z223.1 and National Electrical Code 

ANSI / NFPA 70.

 

z

The cooktops are tested in accordance with ANSI Z21.1 Standard for Household Cooking 

Gas Appliances. These cooktops must be installed in conjunction with a suitable overhead 

vent hood. (See ventilation requirements). Due to the high heat capacity of this unit, 

particular attention should be paid to the hood and duct work installation to ensure it 

meets local building codes. To eliminate risk of burns or fire by reaching over heated 

surface units, cabinet storage located above the surface units should be avoided.

 

z

In Canada: Installation must be in accordance with the current CSA C22.1 Canadian 

Electrical Codes Part 1 and/or local codes. Installation must be in accordance with 

the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical 

installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes 

Part 1 and/or local codes.

Summary of Contents for CDV3-365

Page 1: ...INSTALLATION GUIDE PROFESSIONAL CDV3 365H CDV3 365 CDV3 304H CDV3 304 GAS COOKTOPS US CA...

Page 2: ...any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal...

Page 3: ...avoid overheating z The cooktop must be grounded z Installation must comply with your local building and electricity regulations z Ensure the installer shows the customer where the gas supply shut of...

Page 4: ...oduct to ensure there is no shipping damage If any damage is detected contact the dealer or retailer you bought the product from to report the damage z Fisher Paykel is not responsible for shipping da...

Page 5: ...ht above countertop to top of grates 1 9 16 40 I Distance from right edge of chassis to centre of gas inlet 2 3 4 70 J Distance from rear edge of chassis to centre of gas inlet 1 5 16 33 K Distance fr...

Page 6: ...from right edge of chassis to centre of gas inlet 2 3 4 70 J Distance from rear edge of chassis to centre of gas inlet 1 5 16 33 K Distance from right edge of chassis to centre of power cord 7 8 22 L...

Page 7: ...ventilation hood required 30 762 F Min distance from rear edge of cutout to nearest combustible surface 2 51 CABINETRY DIMENSIONS 36 MODELS IN MM A Min height allowance 4 102 B Depth 19 3 4 502 C Wid...

Page 8: ...defined in National Fuel Gas Code ANSI Z223 1 Current Edition Clearances from non combustible materials are not part of the ANSI Z21 1 scope and are not certified by UL Clearances of less than 6 152m...

Page 9: ...ould be variable to reduce noise and loss of household air z Due to a high volume of ventilation air a source of make up air outside replacement air is recommended This is particularly important for t...

Page 10: ...below Please verify your model s current draw by checking the rating label on the cooktop Required grounding method This appliance is factory equipped with a power supply cord with a three prong grou...

Page 11: ...manual shutoff valve in a location readily accessible by the customer so that gas to the appliance can be shut off in an emergency situation However the appliance must not be modified in any way to ac...

Page 12: ...z Check for a well defined blue flame without any yellow tipping z If any abnormality is evident check that the components of the burner assembly are located properly No air shutter adjustment is pos...

Page 13: ...ight satisfactorily both individually and with other burners operating Flame adjustments made if required FINAL CHECKLIST GAS Connection 1 2 NPT with a minimum 5 8 diameter flex line Site gas supply i...

Page 14: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...

Reviews: