Fisher & Paykel CDV3-365 Installation Manual Download Page 10

10

Gently lower the cooktop into the cutout 
ensuring you have access below the 
countertop to fit and secure the brackets.

Fix the four supplied brackets to the 
base of the cooktop.

Tighten all screws to secure the 
cooktop to the countertop. 
Ensure cooktop is level.

1

2

3

 

z

This cooktop must be grounded.

 

z

Always disconnect electric supply cord from the wall outlet or service disconnect before 
servicing this appliance. 

 

z

Observe all governing codes and ordinances when grounding, in absence of which, observe 
National Electrical Code ANSI / NFPA No. 70.

MODEL

VOLTAGE

MAX. CURRENT

FREQUENCY

CDV3 36" models

120 V

0.10 A

60 Hz

CDV3 30" models

120 V

0.10 A

60 Hz

The electrical supply must be a correctly polarized, grounded 120 V AC, 60 Hz, single phase 
circuit suitable for the maximum current draw of the model, as detailed in the table below. 
Please verify your model’s current draw by checking the rating label on the cooktop.  

Required grounding method

This appliance is factory equipped with a power supply cord with a three-prong grounding 
plug (with polarized parallel blades). It must be plugged into a mating grounding type 
receptacle, connected to a correctly polarized 120 Volt circuit. If the circuit does not have a 
grounding type receptacle, it is the responsibility and obligation of the installer to have the 
existing receptacle changed to a properly grounded and polarized receptacle in accordance 
with all applicable local codes and ordinances by a qualified electrician. In the absence of local 
codes and ordinances, the receptacle replacement shall be in accordance with the National 
Electrical Code. 

The third prong should not, under ANY circumstances, be cut or removed. 

The rating label 

is located on 

the base of the 

cooktop towards 

the front right.

A wiring 

diagram label 

is attached to 

the bottom of 

the cooktop.

INSTALLATION

ELECTRICAL REQUIREMENTS

Summary of Contents for CDV3-365

Page 1: ...INSTALLATION GUIDE PROFESSIONAL CDV3 365H CDV3 365 CDV3 304H CDV3 304 GAS COOKTOPS US CA...

Page 2: ...any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal...

Page 3: ...avoid overheating z The cooktop must be grounded z Installation must comply with your local building and electricity regulations z Ensure the installer shows the customer where the gas supply shut of...

Page 4: ...oduct to ensure there is no shipping damage If any damage is detected contact the dealer or retailer you bought the product from to report the damage z Fisher Paykel is not responsible for shipping da...

Page 5: ...ht above countertop to top of grates 1 9 16 40 I Distance from right edge of chassis to centre of gas inlet 2 3 4 70 J Distance from rear edge of chassis to centre of gas inlet 1 5 16 33 K Distance fr...

Page 6: ...from right edge of chassis to centre of gas inlet 2 3 4 70 J Distance from rear edge of chassis to centre of gas inlet 1 5 16 33 K Distance from right edge of chassis to centre of power cord 7 8 22 L...

Page 7: ...ventilation hood required 30 762 F Min distance from rear edge of cutout to nearest combustible surface 2 51 CABINETRY DIMENSIONS 36 MODELS IN MM A Min height allowance 4 102 B Depth 19 3 4 502 C Wid...

Page 8: ...defined in National Fuel Gas Code ANSI Z223 1 Current Edition Clearances from non combustible materials are not part of the ANSI Z21 1 scope and are not certified by UL Clearances of less than 6 152m...

Page 9: ...ould be variable to reduce noise and loss of household air z Due to a high volume of ventilation air a source of make up air outside replacement air is recommended This is particularly important for t...

Page 10: ...below Please verify your model s current draw by checking the rating label on the cooktop Required grounding method This appliance is factory equipped with a power supply cord with a three prong grou...

Page 11: ...manual shutoff valve in a location readily accessible by the customer so that gas to the appliance can be shut off in an emergency situation However the appliance must not be modified in any way to ac...

Page 12: ...z Check for a well defined blue flame without any yellow tipping z If any abnormality is evident check that the components of the burner assembly are located properly No air shutter adjustment is pos...

Page 13: ...ight satisfactorily both individually and with other burners operating Flame adjustments made if required FINAL CHECKLIST GAS Connection 1 2 NPT with a minimum 5 8 diameter flex line Site gas supply i...

Page 14: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...

Reviews: