Installation instructions
Requirements for alcove or closet installation
Your dryer is approved for installation in an alcove or closet (as specified on the dryer back).
WARNING!
When installing a dryer in a closet alcove it MUST be exhausted to the outdoors. No
other fuel burning appliance can be installed in the same closet or alcove.
The total ventilation area must be a minimum of 60 sq. in. (387 cm
2
) of open area equally
distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of
120 sq. in. (774 cm
2
) of open area equally distributed. The openings must never be obstructed (a
louvered door with the minimum air opening is acceptable). Minimum installation clearances are
required but more clearance is recommended.
1” (25 mm)
1” (25 mm)
1” (25 mm)
min 1” (25 mm)
(rear of product to wall)
minimum clearance
required
56 5/16” (1430 mm)
total ventilation area
120 in.sq (774 cm2)
Fig.4 Minimum clearances
Fig.5 Minimum ventilation
min 2” (50 mm)