Part 2. Specification
Model FSL-124HF
Power supply
V~
,
Hz
,
Ph
220-240,50
,
1
Capacity
W
3550
Input
W
1480
Rated current
A
6.58
Cooling
EER
2,4
Capacity
W 3850
Input
W
1560
Rated current
A
6.95
Heating
COP
2,47
Moisture Removal
L/h
1.2
Max. input consumption
W
1960
Max. current
A
10
Starting current
A
34
Model
PG240X2C-4FT
Type
Rotary
Brand
GD TOSHIBA
Supplier
TOSHIBA(GUANG
DONG)
Capacity
Btu/h
14600/14800
Input
W
1400/1430
Rated current(RLA)
A
6.5
Locked rotor Amp(LRA)
A
7.5
Thermal protector
UP3RE0591-T56
Capacitor
uF
35
Compressor
Refrigerant oil
ml
480
Model
YDK55-4F
Brand
Welling
Input
W
90
Capacitor
uF
4
Indoor fan motor
Speed(hi/lo)
r/min
730/630
Number of rows
3
Tube pitch(a)x row pitch(b)
mm
25.4X22
Fin spacing
mm
1.7
Fin type (code)
Hydrophilic aluminium
Tube outside dia.and type
mm
Ф
9.53, innergroove tube
Coil length x height x width
mm
585X203.2X66
Indoor coil
Number of circuits
2
- 3 -
Summary of Contents for FSL-124HF
Page 9: ...Part 4 Operation Range Ensure the operating temperature is in allowable range 8...
Page 13: ...Part 6 Outlines and Dimension 7 1 Indoor unit FSL 124HF FSL 184HF 12...
Page 14: ...FSL 244HF 7 2 Outdoor unit FSO 124HF 13...
Page 23: ...FSL 184HF Indoor unit FSO 184HF Outdoor unit 22...
Page 34: ...33 33...